00191369-01.pdf - 第155页
User’s Manual SIPLACE HS-50 5 Single Functions Software Version S R.501.xx Edition 01/99 5.2 Single functions, Gantry 153 )XQFWLRQV In the "Rev olver head fun ctions" screen, t he functio ns desc ribed …

5 Single Functions User’s Manual SIPLACE HS-50
5.2 Single functions, Gantry Software Version SR.501.xx Edition 01/99
152
.H\WR)LJ
(1) Gantry functions
(2) Revolver head functions
(3) Vacuum test, revolver head
(4) Nozzle offset, revolver head
(5) Nozzle configuration, revolver head
(6) Nozzle changer configuration, revolver head
NOTE
The current position of the revolver head segment is shown by the graphic above the "Star in
position 1" button.
12345 6

User’s Manual SIPLACE HS-50 5 Single Functions
Software Version SR.501.xx Edition 01/99 5.2 Single functions, Gantry
153
)XQFWLRQV
In the "Revolver head functions" screen, the functions described below are available to help
you test the revolver head.
– Vacuum test in the pick-up position
– Vacuum test in the reject position
– Vacuum test in the holding circuit
– Revolver head functions
The functions are triggered by clicking the appropriate button.
3LFNXSFLUFXLW)RUFHGDLURQRII
When this function is activated, the forced air to the nozzle in the pick-up position is either
switched on or off.
Å In the "Pick-up circuit" area, click the )RUFHGDLURQRIIbutton.
This switches the forced air on or off.
3LFNXSFLUFXLW9DFXXPRQRII
When this function is activated, the vacuum at the nozzle in the pick-up position is either
switched on or off.
Å In the "Pick-up circuit" area, click the 9 DFXXPRQRIIbutton.
This switches the vacuum on or off.
3LFNXSFLUFXLW0HDVXUHIRUFHGDLU
When this function is activated, forced air at the pick-up position is measured.
Å Switch on the forced air (using the "Forced air on/off" function in the "Pick-up circuit" area).
Å Click the 0 HDVXUHIRUF HGDLUbutton in the "Pick-up circuit" area.
The forced air is measured and the result displayed in [mbar] above the button.
NOTE
The value displayed after the measurement is taken does not correspond to the actual values
at the nozzle.
When calibrating the machine, you must use a manometer to establish the values (see Adjust-
ment instructions or the Service Manual).
3LFNXSFLUFXLW0HDVXUHYDFXXP
When this function is activated, vacuum at the pick-up position is measured.
Å Switch on the vacuum (using the "Vacuum on/off" function in the "Pick-up circuit" area).
Å Click the 0HDV XUH9DFXXPbutton in the "Pick-up circuit" area.
The vacuum is measured and the result displayed in [mbar] above the button.
5 Single Functions User’s Manual SIPLACE HS-50
5.2 Single functions, Gantry Software Version SR.501.xx Edition 01/99
154
5HMHFWFLUFXLW)RUFHGDLURQRII
When this function is activated, the forced air at the nozzle in the reject position is switched
on or off.
Å Click the )RUFHGDLURQRIIbutton in the "Reject circuit" area.
The forced air is switched on or off.
5HMHFWFLUFXLW9DFXXPRQRII
When this function is activated, the vacuum to the nozzle in the reject position is switched on
or off.
Å Click the 9DFXXPRQRIIbutton in the "Reject circuit" area.
The vacuum is switched on or off.
+HDGUHIHUHQFHUXQ
This function is used to start a head reference run of all the head axes, or in other words, all
head axes travel to their origin. The gantry axes travel over the reject container and discard
components in a defined manner.
Å Click the +HDGUHIHUHQFHUXQbutton.
The head axes execute a head reference run.
+ROGLQJFLUFXLW0HDVXUHYDFXXP
When this function is activated, the vacuum at the nozzle in the holding circuit is measured.
Å Click the 0HDVXUHYDFXXPbutton in the "Holding circuit" area.
The vacuum is measured and the result displayed in [mbar] above the button.
6WDULQSRVLWLRQ
This function is used to bring the revolver head into a defined starting position.
Å Click the 6WDULQSRVLWLRQbutton.
The revolver head is moved round so that segment 1 is in the pick up and placement posi-
tion (lowest position). In addition the revolver head and the z-axis perform a reference run.
59KHDGLQGH[LQJ
This function is used to move the revolver head. Each time you click the button the revolver
head is moved round by one segment.
Å Click the 59KHDGLQGH[LQJbutton.
The revolver head is moved by one segment.
The current positions of the segments is displayed in the graphic.