User Manual HS-50 1 Introduction
Software Version 5.01 01/99 Issue 1.6 The line concept
23
 7KHOLQHFRQFHSW
 2YHUYLHZ
The placement system can be linked to input and output stations, screen printing systems,
soldering ovens and other automatic placement systems from the SIPLACE range (S-20, F4,
F5 and the SIPLACE G glue application station). All SIPLACE modules are supplied with the
necessary data by the UNIX line computer. The placement system can also be linked to a
higher level data processing system through the use of suitable interfaces.
 7HFKQLFDOGDWDOLQHFRQFHSW
System SIPLACE placement lines
Module SIPLACE HS-50 / SIPLACE 80 S-20/
SIPLACE 80 F4 / SIPLACE 80 F5
Peripherals Input/output stations
Screen printers
Soldering ovens
Inspection stations, etc.
Range of components From 0402 * to 55 mm x 55 mm **
PCB conveyor Automatic width adjustment
PCB format 50 mm x 50 mm to 368 mm x 460 mm
Placement speed Depends on how the modules are connected to one another
Space required 4 m² / SIPLACE 80 modules
7.5 m² / SIPLACE HS-50 modules
* SIPLACE HS-50, SIPLACE 80 S-20 or SIPLACE 80 F4 with 12-segment revolver head
** SIPLACE 80 F4 / F5
1 Introduction User Manual HS-50
1.7 Connection data for the placement system Software Version 5.01 01/99 Issue
24
 &RQQHFWLRQGDWDIRUWKHSODFHPHQWV\VWHP
 (OHFWULFDODQGSQHXPDWLFFRQQHFWLRQSRLQWVRQWKHSODFHPHQWV\VWHP
1. Operating panel, left
2. Main switch
3. Safety doors to the power supply unit
4. Hole for the power cable
5. Operating panel, right
6. Safety doors to the compressed air unit
7. Hole for the compressed air line
8. LAN connection on the station computer
4
A
A
2
1
3
6
5
8
User Manual HS-50 1 Introduction
Software Version 5.01 01/99 Issue 1.8 Technical data - compressed air supply
25
DANGER
The placement system is supplied with 3 x 400 V (3 x 204 V or 3 x 460 V) ± 10%, 50/60 Hz
main power voltage. This means that some parts of the system carry potentially lethal voltages
- even when switched off at the main switch. Incorrect handling of the placement system can
therefore result in death or severe injury or considerable damage to equipment.
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury.
 7HFKQLFDOGDWDHOHFWULFDOUDWLQJV
 7HFKQLFDOGDWDFRPSUHVVHGDLUVXSSO\
Supply voltage 3 x 400 VAC ± 10 %; 50/60 Hz (Europe)
3 x 204 VAC ± 10 %; 50/60 Hz (U.S.A)
3 x 460 VAC ± 10 %; 50/60 Hz
Fuses 3 x 16 A (3 x 400 VAC)
3 x 32 A (3 x 204 VAC)
3 x 16 A (3 x 460 VAC)
Total connected load 10 kVA
Total output 9 kW
Power failure Up to 10 msec
Compressed air pressure supply 5.5 bar ± 0.5 bar
Compressed air consumption 950 Nl/min.
Operating pressure 5.2 bar (fixed)