00191369-01.pdf - 第36页

1 Introduction User Manual HS-50 1.11 Overview of the modules - controls Software Version 5.01 01/99 Issue 34 .H\ ERDUG  A keyboa rd with th e trackbal l is lo cated b eneath eac h scre en. The key boards can be pulled …

100%1 / 442
User Manual HS-50 1 Introduction
Software Version 5.01 01/99 Issue 1.11 Overview of the modules - controls
33
 'HVFULSWLRQ
All the controls can be reached by a 1.60 m tall person.
0DLQVZLWFK
The main switch is used to switch the power supply to the placement system on and off.
RISK OF DEATH
Some parts inside the placement system carry potentially lethal voltages - even when
switched off at the main switch.
.H\VZLWFK
In normal mode, the key switch is set to "0". The key should be removed and kept in a safe
place. It must only be turned to position "I" (set-up mode) by authorized personnel, and then
only for certain maintenance and servicing work.
6WRSEXWWRQ
This button is used to stop the placement system.
6WDUWEXWWRQ
This button starts the placement system after it has been switched on or after faults have been
eliminated.
(PHUJHQF\VWRSEXWWRQ
The emergency stop button latches in the ON position when pressed. The power supply to the
gantry axes, the components change-over tables, conveyors, and used tape cutters is inter-
rupted and the voltage supplied to the star axes of the placement heads is reduced. Turn the
button to release it.
&RPSRQHQWFRXQWHU
The component counter displays the number of components processed.
/&'VFUHHQ
There is a flat LCD screen with a touch-sensitive surface (touch-screen) on either side of the
placement system. The screen resolution is 1024 x 768 pixels.
1 Introduction User Manual HS-50
1.11 Overview of the modules - controls Software Version 5.01 01/99 Issue
34
.H\ERDUG
A keyboard with the trackball is located beneath each screen. The keyboards can be pulled in
and out as required.
,QGLFDWRUODPSV
The sequence of colors is white - green - white. These lamps are used to signal operating sta-
tuses and malfunctions of the placement system.
&RPSRQHQWEDUFRGHUHDGHU
There is a compartment for a Datalogic DL 910 component barcode reader on either side of
the machine. The barcode reader enables the components to be set up and topped up quickly
and reliably.
 (UJRQRPLFDUUDQJHPHQWRIWKHFRQWUROV
Figure 1.11 - 1 on page 1 - 32 provides an overview of the position of the controls, which are sub-
divided into the following groups:
2SHUDWLQJSDQHORQWKHULJKWKDQGVLGHRIWKHFHQWUDOFRQVROHZLWK
LCD screen
Keyboard with trackball
Start button
Component barcode reader
2SHUDWLQJSDQHORQWKHOHIWKDQGVLGHRIWKHFHQWUDOFRQVROHZLWK
LCD screen
Keyboard with trackball
Component counter
Start button
Stop button
–Key switch
Component barcode reader
Main switch
,QSXWRXWSXWVLGHRIWKH3&%FRQYH\RUZLWK
Emergency stop mushroom-head push-buttons
User Manual HS-50 1 Introduction
Software Version 5.01 01/99 Issue 1.11 Overview of the modules - controls
35
 &RQWUROVRQWKHOHIWULJKWKDQGRSHUDWLQJSDQHORIWKHSODFHPHQWV\VWHP
The two operating panels have identical control functions.
0RQLWRUNH\ERDUG6WDUWDQG6WRSEXWWRQV
There is a monitor and a keyboard on both sides of the placement system. They are arranged
so that any person who is at least 1.60 m tall can work comfortably and efficiently.
The Start and Stop buttons are located beneath the keyboard. The on-screen dialog will oc-
casionally prompt you to activate certain actions using buttons, and this arrangement will
make it easier for you both to activate and to interactively control these actions.
.H\VZLWFK
The key switch is located on the left-hand operating panel beneath the Start and Stop buttons.
It is only needed for setting up and servicing work so, for reasons of efficiency, it is positioned
near the Start and Stop buttons.
0DLQVZLWFK
The main switch is part of the power supply unit, so it is positioned on the left-hand operating
panel. It is located here because it is only needed for servicing and maintenance work. With
respect to its infrequent use the switch is still ergonomically positioned.
&RPSRQHQWEDUFRGHUHDGHU
The four component tables for supplying components are arranged on the right and left of the
placement system. For this reason, the component barcode readers are also located in the
central consoles, since it enables the operators to work comfortably and efficiently during the
component set-up and filling checks.
 &RQWUROVRQWKHLQSXWDQGRXWSXWVLGHRIWKHSODFHPHQWV\VWHP
The controls on the input and output side of the placement system are identical.
(PHUJHQF\VWRSPXVKURRPKHDGSXVKEXWWRQDQG6WDUWEXWWRQ
An emergency stop mushroom-head push-button and two Start buttons are located on both
the input and the output side of the PCB conveyor. This arrangement was adopted for the
emergency stop mushroom-head push-buttons because it enables them to be reached quickly
and easily from any position.
In addition, it is important to have an unrestricted view of the placement heads and placement
area during maintenance, servicing and setting up work in order to be able to check all the
operations carried out inside the machine. This is particularly important during testing phases
or when starting single functions, for example.