00191369-01.pdf - 第27页

User Manual HS-50 1 Introduction Software Version 5.01 01/99 Issue 1.8 Technical data - compressed air supply 25 DANGER The place ment sys tem is s upplied w ith 3 x 40 0 V (3 x 204 V o r 3 x 46 0 V) ± 10%, 50/60 Hz main…

100%1 / 442
1 Introduction User Manual HS-50
1.7 Connection data for the placement system Software Version 5.01 01/99 Issue
24
 &RQQHFWLRQGDWDIRUWKHSODFHPHQWV\VWHP
 (OHFWULFDODQGSQHXPDWLFFRQQHFWLRQSRLQWVRQWKHSODFHPHQWV\VWHP
1. Operating panel, left
2. Main switch
3. Safety doors to the power supply unit
4. Hole for the power cable
5. Operating panel, right
6. Safety doors to the compressed air unit
7. Hole for the compressed air line
8. LAN connection on the station computer
4
A
A
2
1
3
6
5
8
User Manual HS-50 1 Introduction
Software Version 5.01 01/99 Issue 1.8 Technical data - compressed air supply
25
DANGER
The placement system is supplied with 3 x 400 V (3 x 204 V or 3 x 460 V) ± 10%, 50/60 Hz
main power voltage. This means that some parts of the system carry potentially lethal voltages
- even when switched off at the main switch. Incorrect handling of the placement system can
therefore result in death or severe injury or considerable damage to equipment.
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury.
 7HFKQLFDOGDWDHOHFWULFDOUDWLQJV
 7HFKQLFDOGDWDFRPSUHVVHGDLUVXSSO\
Supply voltage 3 x 400 VAC ± 10 %; 50/60 Hz (Europe)
3 x 204 VAC ± 10 %; 50/60 Hz (U.S.A)
3 x 460 VAC ± 10 %; 50/60 Hz
Fuses 3 x 16 A (3 x 400 VAC)
3 x 32 A (3 x 204 VAC)
3 x 16 A (3 x 460 VAC)
Total connected load 10 kVA
Total output 9 kW
Power failure Up to 10 msec
Compressed air pressure supply 5.5 bar ± 0.5 bar
Compressed air consumption 950 Nl/min.
Operating pressure 5.2 bar (fixed)
1 Introduction User Manual HS-50
1.8 Technical data - compressed air supply Software Version 5.01 01/99 Issue
26
 7HFKQLFDOGDWDFRPSUHVVHGDLUVSHFLILFDWLRQ
Maximum particle size by density, based on ISO/DIS 8573-1 (class 1)
 7HFKQLFDOGDWDQRLVHHPLVVLRQV
 7HFKQLFDOGDWDDGPLVVLEOHHQYLURQPHQWDOLQIOXHQFHV
Particle size 0.1 µm
Particle density 0.2 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Dew point under pressure (class 4) Dew point +3°
Maximum noise generation 74 dB (A)
Ambient temperature Between 15°C and 35°C
Atmospheric humidity 30 to 75%
(but no higher than 45% on average in order to prevent any
possibility of condensation on the machine.)