00191369-01.pdf - 第39页
User Manual HS-50 1 Introduction Software Version 5.01 01/99 Issue 1.12 Overview of the modules - gantries 37 2YHUYLHZ RIWKHPRGXOHVJ DQWULHV 3RVLWLRQRIWKHJDQWULHV 1. Gantry 1 ( sector 1) 2. Gantry …

1 Introduction User Manual HS-50
1.11 Overview of the modules - controls Software Version 5.01 01/99 Issue
36
7HFKQLFDOGDWD3&%EDUFRGHUHDGHU
Connected to Station computer
Data entry Via barcode scanner or keyboard
Number of characters Up to 40
Not admissible Barcodes starting with a 1, 2, 3, or 4
of less than 5 characters long
Number of barcodes Up to 6 per component
Filter for masking out data Up to 1 per barcode
Preset code types Code 39 (standard or ASCII)
Code 2 of 5 interleaved and normal,
Code 128, UPC/EAN/JAN codes
(others available upon request)

User Manual HS-50 1 Introduction
Software Version 5.01 01/99 Issue 1.12 Overview of the modules - gantries
37
2YHUYLHZRIWKHPRGXOHVJDQWULHV
3RVLWLRQRIWKHJDQWULHV
1. Gantry 1 (sector 1)
2. Gantry 2 (sector 2)
3. Gantry 3 (sector 3)
4. Gantry 4 (sector 4)
The gantry system consists of two functional groups
–x axis
–y axis
4
1
2
3

1 Introduction User Manual HS-50
1.12 Overview of the modules - gantries Software Version 5.01 01/99 Issue
38
6WUXFWXUHRIWKH[D[LV
The x axis essentially consists of the following main modules:
– gantry arm (1)
– head mount (2)
– linear measuring system (3)
– x axis guide system (4)
– x axis three-phase AC servomotor (5)
The head mount holds the following components
– sub-gantry camera (camera for the PCB vision system)
– head board
– measuring head for the x axis measuring system
– revolver placement head
5
1
2
4
3