6 Vision functions User Manual HS-50
6.5 Teach Fiducial Software-Version 5.01 Edition 01/99
218
NOTE:
Buttons are active when the text on the button is black (rather than gray). This means that you can
launch the associated function by clicking on the button with the mouse.
The 6HDUFKDUHDbuttonwill, for example, only be active if you have
already loaded a fiducial or
created a new fiducial.
A model must already exist for the selected fiducial.
If a new fiducial number has been input then you can select the 6WDQGDUGYDOXHV options. If you
have loaded an existing fiducial all options will be accessible. In the menu the following options
will be available:
Changing the parameters of the fiducial structure fields (template)
Changing the parameters of the search area
Teaching with standard values
Fiducial structure field parameters are
–width,
height and
camera resolution
Search area parameters are
width and
height
The parameters are stored in a list in the station computer. This list is initialized with default and
current values when the /RDGILGXFLDO option is launched.
If you change a parameter, a teach command will be generated in the machine controller (MC).
The only parameter block which will be added to the teach command in the general parameters
will be the block which has been changed.
For this reason the machine controller generates three different teach commands:
Teach with standard values
Teach the search area
Teach the fiducial structure field (template)
User Manual HS-50 6 Vision functions
Software-Version 5.01Edition 01/99 6.5 Teach Fiducial
219
 6 WDQGDUG9DOXHV2SWLRQ
When this option is selected
the menu is closed.
the teaching process is launched.
the video image is shown with fiducial, fiducial structure field and uniqueness value.
header and footer with commentary, measurement results, key assignments and command se-
quences will be displayed.
The teaching process will now be launched with the standard values. The result of the teaching
process is the uniqueness value which is shown in the header of the video image. This value pro-
vides information on the differentiation quality of the fiducial with respect to other structures in the
vicinity of the fiducial. The figure displayed may range between
0 = unsatisfactory and
100 = very good differentiation capability.
Practice shows that a uniqueness value of at least 60 must be achieved for fiducials and ink dots.
teach
1..6 : x/y step
Fiducial No. = 8 Uniqueness = 70
Ret :
Standard values
x/y step width = ...
: x axis +
: x axis -
: y axis +
: y axis -
6 Vision functions User Manual HS-50
6.5 Teach Fiducial Software-Version 5.01 Edition 01/99
220
NOTE
If you wish to use a fiducial despite the fact that it has a low uniqueness value, you should ensure
that the fiducial has a good quality value (see Section 6.5.6.2 on page ).
If the quality is bad as well, it would be better to select another fiducial (see Criteria for Creating
Fiducials in Section 6.2.5 on page 6 - 190).
Å Use the arrow keys to change the camera position. You can vary the step width by entering a
number in the range 1 - 6.
Å Press the 5HWXUQ key to repeat the teaching process.
Å Press (VF to quit the teaching process. The video image disappears and the 7HDFKILGXFLDO
menu is displayed once more.
 +LJK0LGGOHDQG/RZ5HVROXWLRQ2SWLRQV
When you select one of these options,
the menu closes,
the video image is shown with fiducial and search area, and
header and footer with commentary, measurement results, key assignments and command se-
quences are displayed.
Fiducial No. = 8 Uniqueness = 70
Blank: hor./vert.
Tab : field step
Template high res.
1..6 : x/y step
: x axis +
: x axis -
: y axis +
: y axis -
x/y step width = ...Direction = ...
Field step = ...
Ret: teach
- : smaller
+ : larger