User’s Manual SIPLACE HS-50 5 Single Functions Software Version S R.501.xx Edition 01/99 5.2 Single functions, Gantry 155 $ FWXDWH'3 D[L V When this functio n is a ctivated, the nozz le in the dp1 ax is is rota…
5 Single Functions User’s Manual SIPLACE HS-50
5.2 Single functions, Gantry Software Version SR.501.xx Edition 01/99
154
5HMHFWFLUFXLW)RUFHGDLURQRII
When this function is activated, the forced air at the nozzle in the reject position is switched
on or off.
Å Click the )RUFHGDLURQRIIbutton in the "Reject circuit" area.
The forced air is switched on or off.
5HMHFWFLUFXLW9DFXXPRQRII
When this function is activated, the vacuum to the nozzle in the reject position is switched on
or off.
Å Click the 9DFXXPRQRIIbutton in the "Reject circuit" area.
The vacuum is switched on or off.
+HDGUHIHUHQFHUXQ
This function is used to start a head reference run of all the head axes, or in other words, all
head axes travel to their origin. The gantry axes travel over the reject container and discard
components in a defined manner.
Å Click the +HDGUHIHUHQFHUXQbutton.
The head axes execute a head reference run.
+ROGLQJFLUFXLW0HDVXUHYDFXXP
When this function is activated, the vacuum at the nozzle in the holding circuit is measured.
Å Click the 0HDVXUHYDFXXPbutton in the "Holding circuit" area.
The vacuum is measured and the result displayed in [mbar] above the button.
6WDULQSRVLWLRQ
This function is used to bring the revolver head into a defined starting position.
Å Click the 6WDULQSRVLWLRQbutton.
The revolver head is moved round so that segment 1 is in the pick up and placement posi-
tion (lowest position). In addition the revolver head and the z-axis perform a reference run.
59KHDGLQGH[LQJ
This function is used to move the revolver head. Each time you click the button the revolver
head is moved round by one segment.
Å Click the 59KHDGLQGH[LQJbutton.
The revolver head is moved by one segment.
The current positions of the segments is displayed in the graphic.

User’s Manual SIPLACE HS-50 5 Single Functions
Software Version SR.501.xx Edition 01/99 5.2 Single functions, Gantry
155
$FWXDWH'3D[LV
When this function is activated, the nozzle in the dp1 axis is rotated by 90
0
.
Å Click the $FWXDWH'3D[LVbutton.
The nozzle in the dp1 axis is rotated by 90
0
once.
*DQWU\IXQFWLRQVVFUHHQ
Å In the current screen for the single functions for Gantry x, click the symbol .
The user interface is switched to the "Gantry functions" screen (see Fig. 5.2 - 2
).

5 Single Functions User’s Manual SIPLACE HS-50
5.2 Single functions, Gantry Software Version SR.501.xx Edition 01/99
156
NOTE
All travel functions of the main axes (x and y) must be started using the start button.
A message appears in the status field on the screen which asks you to "Please press the start
button".
If the machine covers are not closed, the message "Close cover" will appear in the status
field.
)XQFWLRQV
In the "Gantry functions" screen the following functions are available to test the currently se-
lected gantry. The required function is triggered by clicking on the corresponding button.
*RWRVHWXSSRVLWLRQ
This function is used to check the set-up position of the gantry.
When the gantry is in the set-up position, it is possible to unload and retool the feeders.
Å Click the *RWRVHWXSSRVLWLRQbutton and press the start button as often as you are asked
to.
The gantry moves (from the feeder area) into the set-up position.
*RWRVHUYLFHSRVLWLRQ
This function is used to check the service position of the gantry.
When the gantry is in the service position, it is possible to carry out work on the placement
head and on other parts of the gantry.
Å Click the *RWRVHUYLFHSRV¶Qbutton and press the start button as often as you are asked
to. The gantry moves into the service position.
*RWRZDLWLQJSRVLWLRQ
This function is used to check the waiting position of the gantry.
When the gantry is not required for placement, it moves to the waiting position.
Å Click the *RWRZDLWLQJSRV¶Qbutton and press the start button as often as you are asked
to. The gantry moves into the waiting position.