00191369-01.pdf - 第177页
User’s Manual SIPLACE HS-50 5 Single Functions Software Version S R.501.xx Edition 01/99 5.3 Single functions, Transpo rt 175 The conve yors a re traveli ng at th e set spe ed. All func tions are locked. Å Click t he…

5 Single Functions User’s Manual SIPLACE HS-50
5.3 Single functions, Transport Software Version SR.501.xx Edition 01/99
174
5HIUHVK
The "Refresh" function is used to check whether the ultrasonic sensors for the whole of the
transport conveyor are adjusted correctly. To do this, position a board over one of the sen-
sors.
The most recent states of the light barriers for the input conveyor (IC), processing conveyor 1
(PC1), intermediate conveyor (IC), processing conveyor 2 (PC2) and output conveyor (OC)
are displayed above the "Refresh" button. When you execute the "Refresh" function the cur-
rent states are queried and the results displayed (see Fig. 5.3 - 1
).
Å Position a board over the sensor for the required conveyor.
Å Click the 5HIUHVKbutton in the "Sensor state" area.
The sensors are updated and the result is displayed over the button.
There are two possible states for each sensor:
1 = The sensor has responded.
There is a board on this conveyor.
0 = The sensor has not responded.
There is no board on this conveyor.
Å Repeat the process for each of the transport conveyors, if necessary.
2Q
This function can be used to check the conveyors at both slow and high speed. The input con-
veyor only travels at high speed.
NOTE
The conveyor must be empty before carrying out this function.
Å Click the 3&%WRRXWSXWFRQYbutton in "Processing area 2" to empty the conveyor.
Å Activate the "High speed" check box in the "Conveyor" area if the conveyor is to travel at
high speed.
Å Deactivate the check box if the conveyor is to travel at the slower speed.
NOTE
The input conveyor only travels at high speed.
Å Click the 2Qbutton. This opens the following dialog box.

User’s Manual SIPLACE HS-50 5 Single Functions
Software Version SR.501.xx Edition 01/99 5.3 Single functions, Transport
175
The conveyors are traveling at the set speed.
All functions are locked.
Å Click the 2. button in this dialog box if the operation is to be stopped.
The conveyors will be stopped and the dialog box closed.
All functions are then released.

5 Single Functions User’s Manual SIPLACE HS-50
5.3 Single functions, Transport Software Version SR.501.xx Edition 01/99
176
3&%FRQYH\RUZLGWKVFUHHQ
Å In the "Transport functions" screen, click the symbol.
The user interface is switched to the "PCB conveyor width" screen (see Fig. 5.3 - 2
).
CAUTION
Before adjusting the conveyor width, make sure there are no boards or other objects on the
machine’s conveyors. Failure to do so may result in damage to both machine and boards!