6 Vision functions User Manual HS-50 6.6 Test Component Software-Version 5.01 Edition 01/99 284 – va ry the integ ratio n setting s. 5HVROXWLRQI RUWKHDQJO HFDOFXODWLRQ In this me asuring mode, if the com ponent rot…

User Manual HS-50 6 Vision functions
Software-Version 5.01Edition 01/99 6.6 Test Component
283
*)
L applies to irregularly shaped components with separate windows
µ6L]H¶PHDVXULQJPRGH
Click on the ‘Setting’ field for the ‘Size’ measuring mode to overlay the 6L]HPHDVXULQJPRGH
menu on the screen.
This menu is used to
– vary the resolution the angle calculation.
– specify the method for the rotation calculation and
Bare dies S
&RPSRQHQW
0HDVXUHPHQWVHTXHQFH
6 5 * & / %
Tab. 6.6.1

6 Vision functions User Manual HS-50
6.6 Test Component Software-Version 5.01 Edition 01/99
284
– vary the integration settings.
5HVROXWLRQIRUWKHDQJOHFDOFXODWLRQ
In this measuring mode, if the component rotation has been calculated incorrectly on account of
ambiguity, you can increase the angular resolution in order to determine the angle of rotation. The
following increments may be used in relation to the resolution in order to determine the angle of
the components:
– Low resolution:
– Medium resolution
Determining the angle every 4° within the angular tolerance
– High resolution
Determining the angle every 2° within the angular tolerance
– Very high resolution
Determining the angle every 1° within the angular tolerance
0HWKRGIRUFDOFXODWLQJWKHURWDWLRQ
Here you must specify the number of rotation windows in order to determine the angle:
– Automatic selection
The system selects the number of windows.
– SWIN method (Single Window)
Selects a single window. This method is suitable for small components and fluctuating dimen-
sions.
$ QJXODUWROHUDQFH
Determining the
angle for the
following
angles
- Angular tolerance
2
- 15° - 33°
0° - 8° - 18°
+Angular tolerance
2
0° - 8°
8° 0°
15° 8°
18°
33°
Tab. 6.6.2

User Manual HS-50 6 Vision functions
Software-Version 5.01Edition 01/99 6.6 Test Component
285
– TWIN method (Two Windows)
Two windows are selected. This method is particularly suitable for rapid analysis, for PLCCs,
for example. However, this requires the structures to be investigated to lie in the center of the
window. If this is not the case, select just one window (SWIN method).
,QWHJUDWLRQVHWWLQJV
If you click on the 'Integration settings' field, the ,QWHJUDWLRQVHWWLQJVRI6L]HPHDVXULQJPRGH
menu will appear on screen.
This menu is used to select the
– integration direction,
– the resolution in the measuring direction and
– the resolution in the integration direction.
,QWHJUDWLRQGL UHF WL RQ