6 Vision functions User Manual HS-50 6.6 Test Component Software-Version 5.01 Edition 01/99 284 – va ry the integ ratio n setting s. 5HVROXWLRQI RUWKHDQJO HFDOFXODWLRQ  In this me asuring mode, if the com ponent rot…

100%1 / 442
User Manual HS-50 6 Vision functions
Software-Version 5.01Edition 01/99 6.6 Test Component
283
*)
L applies to irregularly shaped components with separate windows
 µ6L]H¶PHDVXULQJPRGH
Click on the ‘Setting’ field for the ‘Size’ measuring mode to overlay the 6L]HPHDVXULQJPRGH
menu on the screen.
This menu is used to
vary the resolution the angle calculation.
specify the method for the rotation calculation and
Bare dies S
&RPSRQHQW
0HDVXUHPHQWVHTXHQFH
6 5 * & / %
Tab. 6.6.1
6 Vision functions User Manual HS-50
6.6 Test Component Software-Version 5.01 Edition 01/99
284
vary the integration settings.
5HVROXWLRQIRUWKHDQJOHFDOFXODWLRQ
In this measuring mode, if the component rotation has been calculated incorrectly on account of
ambiguity, you can increase the angular resolution in order to determine the angle of rotation. The
following increments may be used in relation to the resolution in order to determine the angle of
the components:
Low resolution:
Medium resolution
Determining the angle every 4° within the angular tolerance
High resolution
Determining the angle every 2° within the angular tolerance
Very high resolution
Determining the angle every 1° within the angular tolerance
0HWKRGIRUFDOFXODWLQJWKHURWDWLRQ
Here you must specify the number of rotation windows in order to determine the angle:
Automatic selection
The system selects the number of windows.
SWIN method (Single Window)
Selects a single window. This method is suitable for small components and fluctuating dimen-
sions.
$ QJXODUWROHUDQFH   
Determining the
angle for the
following
angles
- Angular tolerance
2
- 15° - 33°
- 8° - 18°
+Angular tolerance
2
- 8°
15°
18°
33°
Tab. 6.6.2
User Manual HS-50 6 Vision functions
Software-Version 5.01Edition 01/99 6.6 Test Component
285
TWIN method (Two Windows)
Two windows are selected. This method is particularly suitable for rapid analysis, for PLCCs,
for example. However, this requires the structures to be investigated to lie in the center of the
window. If this is not the case, select just one window (SWIN method).
,QWHJUDWLRQVHWWLQJV
If you click on the 'Integration settings' field, the ,QWHJUDWLRQVHWWLQJVRI6L]HPHDVXULQJPRGH
menu will appear on screen.
This menu is used to select the
integration direction,
the resolution in the measuring direction and
the resolution in the integration direction.
,QWHJUDWLRQGL UHF WL RQ