1 Introduction 1.4 Staff qualifications and training Assembly Instructions / Montageanleitung SIPLACE TX-Series, X-Series S, SX1/SX2 V2 Option PCB Barcode / LP-Barcode (Lector 620) 05/2019 81 1.4 Staff qualifications and…

1 Introduction
1.3 Other instructions
80 Assembly Instructions / Montageanleitung SIPLACE TX-Series, X-Series S, SX1/SX2 V2
Option PCB Barcode / LP-Barcode (Lector 620) 05/2019
1.3.3.5 Dispatching ESD modules
► Always store modules and components in conductive packaging (e.g. metallized plastic bags
or metal sleeves) and dispatch them in conductive packaging
► If the packaging is not conductive, place the modules in a conductive envelope before pack-
aging. Use conductive expanded rubber, ESD bags, domestic aluminum foil or paper, for
example. NEVER use plastic bags or film.
► If the module has integral batteries, ensure that the conductive packaging does not touch or
short circuit the battery terminals and, if necessary, first cover the terminals with insulating
tape or material.
1.3.4 Validity of Document
The work described in this manual is divided into modules and is largely identical for all machine
types:
●
If the work required for specific machines differs from the standard procedure, this will be in-
dicated with reference to the machine number, series and delivery state.
●
Illustrations are only shown as examples, for example, the illustration of a SIPLACE X4 or a
machine with different paint finish does not imply that the information following the illustration
only applies to the shown machine type.
The manual focuses on describing mechanical work.
Please refer to the circuit diagram folder for any electrical checks:
●
Detailed circuit diagrams folder for SIPLACE TX V1-Series (up to no. 499) [DE+EN: 00197933-xx]
●
Detailed circuit diagrams folder for SIPLACE TX V1-Series (from no. 500) [DE
+EN:00198274-xx]
●
Detailed circuit diagrams SIPLACE TX V2-Series [DE+EN: 00198460-xx]
●
Detailed circuit diagrams folder for SIPLACE X-Series S (up to Gxxxx) [DE+EN:00197021‑xx]
●
Detailed circuit diagrams folder for SIPLACE X-Series S (from Hxxxx) [DE+EN:00197920‑xx]
●
Detailed circuit diagrams folder for SIPLACE SX1/SX2 V2 (from Nxxxx) [DE+EN:00197899-xx]
●
SIPLACESX4/DX4 detailed circuit diagrams [DE+EN: 00196711-xx]
1.3.5 Release History
Document
SIPLACE TX-Series, X-Series S, SX1/SX2 V2
Option PCB Barcode (Lector 620)
Assembly Instructions
Release Amendments
04/2014 Initial release
05/2017 Supplements and corrections:
●
SIPLACE SX1/SX2 from N001, TX-Series
●
Installing the LAN card
●
Reference to software settings in document [00198203‑xx]
05/2019 Supplements and corrections:
●
Safety instructions – updated
●
Photos of barcode scanner and mounting rail – updated (new version)
●
Detailed routing of cables – supplemented
●
BoxPC iBase – supplemented
●
Scope of delivery – updated

1 Introduction
1.4 Staff qualifications and training
Assembly Instructions / Montageanleitung SIPLACE TX-Series, X-Series S, SX1/SX2 V2
Option PCB Barcode / LP-Barcode (Lector 620) 05/2019
81
1.4 Staff qualifications and training
Qualified or adequately trained personnel means that these people are familiar with the setting up,
operation and maintenance of the machine and the add-on devices and are suitably qualified, e.g.:
●
Have been trained, instructed or authorized to switch on and off, isolate, earth and identify
electrical circuits and system components in accordance with normal safety standards.
●
Have been trained or instructed in the upkeep and use of appropriate safety equipment in
accordance with normal safety standards.
●
Have received first aid training.

1 Introduction
1.4 Staff qualifications and training
82 Assembly Instructions / Montageanleitung SIPLACE TX-Series, X-Series S, SX1/SX2 V2
Option PCB Barcode / LP-Barcode (Lector 620) 05/2019