3 Installation 3.5 Attaching the tape measure 96 Assembly Instructions / Montageanleitung SIPLACE TX-Series, X-Series S, SX1/SX2 V2 Option PCB Barcode / LP-Barcode (Lector 620) 05/2019 3.5 Attaching the tape measure Fig.…

3 Installation
3.4 Mounting the 2D PCB Barcode Scanner at the Bottom
Assembly Instructions / Montageanleitung SIPLACE TX-Series, X-Series S, SX1/SX2 V2
Option PCB Barcode / LP-Barcode (Lector 620) 05/2019
95
Fig.33: Top PCB barcode reader assembly
► Use the six screws of type DIN 7984-
M4 x 6-A2-70 [03127570‑xx](1) to
mount the whole assembly in the hand
guard.
Fig.34: Fastening the trailing chain
► Attach the other end of the trailing
chain on the opposite side of the hand
guard at position(1). To do so, use the
M3x8 countersunk screws.
3.4 Mounting the 2D PCB Barcode Scanner at the Bottom
► Mounting the bottom 2D PCB barcode scanner assembly is identical to mounting the top 2D
PCB barcode scanner assembly (see section 3.3 "Mounting the 2D PCB Barcode Scanner at
the Top" [}92]).
Leave the assembly plate on the assembly kit when fitting the bottom PCB barcode scanner.
Fig.35: Mounting the PCB barcode scanner assembly at the
bottom
► Use the five M4x6 screws (1) to fix the
assembly to the hand guard.

3 Installation
3.5 Attaching the tape measure
96 Assembly Instructions / Montageanleitung SIPLACE TX-Series, X-Series S, SX1/SX2 V2
Option PCB Barcode / LP-Barcode (Lector 620) 05/2019
3.5 Attaching the tape measure
Fig.36: Attaching the tape measure
► Attach the tape measure (1).
NOTICE!
The tape measure is intended for
manual control only.
The exact position and orientation of
the tape measure can be customized.
We recommend to align the tape
measure in accordance with the fixed
conveyor rail position.
.
3.6 Installing the hand guard
Fig.37: Hand guard
► Fit the hand guard(1) [03100338‑xx]
into the input conveyor extension (for
top barcode option: together with the
barcode scanners mounted on top of
the hand guard)
Fig.38: Warning strips
► Attach the yellow and black warning
strip to the bottom edge of the hand
guard.

3 Installation
3.7 Installing the LAN card in the BoxPC
Assembly Instructions / Montageanleitung SIPLACE TX-Series, X-Series S, SX1/SX2 V2
Option PCB Barcode / LP-Barcode (Lector 620) 05/2019
97
3.7 Installing the LAN card in the BoxPC
SIPLACE SX1/SX2 from serial no. Nxxxx
► Install the LAN card "LAN card PCI Gigabit SEMPRE NC1000-1" [03112190-xx] in the
"BoxPC ABP402-A CPU1020E 2xPCI SSD (iBase)" [03120423-xx].
For more information, see the service manual for your machine or read section 5.3.1 "Repla-
cing the LAN card" [}124] (identical procedure).
SIPLACE X-Series S up to serial no. Gxxxx:
► For these machines, no LAN card is required.
SIPLACE X-Series S from serial number Hxxxx onwards and
SIPLACE TX-Series:
► Install the LAN card "LAN card PCI Express 2x Gigabit LAN" [03118416‑xx] in the BoxPC
427D [03114177‑xx].
For more information, see the service manual for your machine or read section 5.3.2 "Repla-
cing the GigE Ethernet Adapter" [}125] (identical procedure).
3.8 Running and Connecting the Cable
SIPLACE SX1/SX2 from serial no. Nxxxx
► Continue with section 3.8.1 "SIPLACE SX1/SX2: Running and connecting the cable" [}97].
SIPLACE X-Series S:
► Continue with section 3.8.2 "SIPLACE X-Series S: Running and connecting cables" [}101].
SIPLACE TX-Series:
► Continue with section 3.8.3 "SIPLACE TX-Series: Running and connecting the cable" [}107].
3.8.1 SIPLACE SX1/SX2: Running and connecting the cable
The connectors for the PCB barcode readers are located on the conveyor control units.
The conveyor control units are located in the input area of the conveyor.
Removing the covers
Fig.39: Removing the cover plates
► Undo the four screws fastening the
holding plate(1) and then remove the
holding plate.
► Remove the covers(2) on top of the
conveyor control units.
Fig.40: Cable duct cover
► Remove the screw(2) fastening the
cover(1) on top of the cable duct and
remove the cover.