00198371-01_UM_SWS-EN.pdf - 第101页

User manual SIPLACE Wafer System (SWS) 5 SWS tasks Edition 04/2018 5.9 Controls and displays 101 5.9.2 Description All the controls can be reached by a 1.40 m t all person. Main switch The main switch is used for switchi…

100%1 / 142
5 SWS tasks User manual SIPLACE Wafer System (SWS)
5.9 Controls and displays Edition 04/2018
100
5.9 Controls and displays
5.9.1 Overview
5
Fig. 5.9 - 1 Controls and displays
(1) Main switch (3) LCD touchscreen
(2) EMERGENCY STOP button (4) Keyboard
(1)
(2)
(3)
(4)
User manual SIPLACE Wafer System (SWS) 5 SWS tasks
Edition 04/2018 5.9 Controls and displays
101
5.9.2 Description
All the controls can be reached by a 1.40 m tall person.
Main switch
The main switch is used for switching the power supply to the SWS on and off.
5
EMERGENCY STOP button
The EMERGENCY STOP button latches in the ON position when pressed. The power supply will
be interrupted. Turn the button to release it.
LCD touchscreen
Each SWS features a flat screen monitor with LCD technology and touchscreen function for op-
eration of the SWS software.
Keyboard
The keyboard is located beneath the monitor.
5
USB connection
5
Fig. 5.9 - 2 USB connection
There is a USB connection next to the LCD screen (1).
DANGER
Lethal voltages!
Some parts inside the SWS carry potentially lethal voltages - even when switched off at
the main power switch.
CAUTION
Risk of collision on the monitor with keyboard
When working on the SWS, there is risk that you could collide with the monitor and key-
board.
Turn the monitor and keyboard away to the side.
Make sure that you are not under the monitor and keyboard with your head.
(1)
5 SWS tasks User manual SIPLACE Wafer System (SWS)
5.9 Controls and displays Edition 04/2018
102
5.9.3 Ergonomic arrangement of controls
Fig. 5.9 - 1, page 100 provides an overview of the position of the controls. They are subdivided
into the following groups:
LCD touchscreen
Keyboard
EMERGENCY STOP button
Main switch
5.9.3.1 Controls on the control panels
The two operator panel have identical control functions.
Monitor and keyboard,
The SIPLACE Wafer System has a monitor and keyboard attached.
Main switch
The main power switch is part of the power module. It is located here because it is only needed
for servicing and preventive maintenance work and is therefore not subject to frequent use.