For SIPLACE D1 only:
Clean the IC and FC camera 5
There is a risk of cutting your finger along the edges of the mirror. 5
To protect your hands, wear laboratory gloves and avoid touching the edges. 5
5
The laboratory gloves are also essential for effective cleaning (fingerprints). 5
5
a Carefully pull the top part of the IC camera up and off.
s Clean the tilted glass plate with a lens cloth.
5
: Insert the top part of the IC camera.
When you insert the top part of the IC camera, make sure that it lies flat against the bottom part
and does not move.
5
d Remove the top part of the FC camera in the same way.
f Clean the tilted glass plate with a lens cloth.
5
: Insert it once more.
5
For SIPLACE D1 only:
Clean the coplanarity module (if present) 5
: Use lens cleaning cloth to clean the lenses of the coplanarity module.
5
5
: Switch the placement machine on at the main switch.
: Dock the component trolley in the placement machine.