: Place a catch tray beneath the compressed air maintenance unit.
a Press the drain nozzle on the condensate tank to release the pressure and to drain den con-
densate.
6
s Remove the condensate tank by turning it counter-clockwise and then pulling it down and out
(bayonet fitting).
d Unscrew the filter casing from the compressed air maintenance unit.
: Replace the filter if it is dirty.
: Reverse the sequence described above to refit the filter and filter casing.