00194845-0302_MM_D1_D2_EN.pdf - 第76页
9 Maintain the sleeves SIPLA CE D1 / D2 02/2010 EN E dition 76 9 Maint ain the sleeves 9

SIPLACE D1 / D2 8 Annual maintenance work
02/2010 EN Edition
75
8
For maintenance of the P&P module you will need: 8
– Lint-free cloths
– Ethyl alcohol
– Compressed air
– ESD wristband.
8
: End the placement sequence and set down the nozzles of the P&P module.
: Dock the component trolley out of the placement machine or move the P&P module to a point
at which the Z axis can be extended down safely.
: Switch the placement machine off at the main switch.
8
The easiest position at which to carry out the conversion is location 2. 8
8
8
8
Wear an ESD armband for the whole time you are working on the placement head and servos. 8
8
Clean /check additional volume filter 8
8
Keep your hand underneath the cap as you remove it as the filter can drop out. 8
8
a Loosen the union nut and detach the compressed air hose.
The additional volume filter will drop out.
: Clean the filter by carefully blowing it out with compressed air.
: Check the filter for damage.
Replace it if it is damaged.
: Insert the filter once more and tighten the union nut.
: Make sure that the compressed air hose can move freely when the Z axis moves, that it is not
jammed at any point and does not obstruct the Z axis.
Clean the scale 8
: Carefully press the Z axis down in the vicinity of the return cylinder.
d Carefully clean the scale using a lint-free cloth moistened with ethyl alcohol.
8
Only use a little ethyl alcohol and do not press too hard, otherwise the glued-on scale may become
detached. 8

9 Maintain the sleeves SIPLACE D1 / D2
02/2010 EN Edition
76
9 Maintain the sleeves
9

SIPLACE D1 / D2 9 Maintain the sleeves
02/2010 EN Edition
77
9
You will need the following tools and consumables for maintaining the sleeves: 9
– Laboratory gloves
– Ethyl alcohol
– Lint-free cloths
– Cottonwool buds
– Microtips (cottonwool buds)
– Drill bit, 1.1 mm
– Drill bit, 1.4 mm
– Fin Grease spray grease
– UNISILKON L250L
– Suction plate.
SIPLACE sleeve maintenance:
12-segment C&P head (item no. 00375681-01). 9
9
a Check the film for damage.
If the film is damaged, send the sleeve to SIPLACE Sleeve Maintenance.
9
s Spray a little Teflon grease into a suitable container.
Moisten the cottonwool bud with Teflon grease.
Do not spray the Teflon grease directly from the spray can to avoid over-application, and thus
damage to the placement head!
9
Only use ethyl alcohol for cleaning. Do not use surgical spirit otherwise smearing will occur on the
incremental disk. 9
Do not use silicone-soluble cleaning agents. 9
9
d Run the lightly moistened cottonwool bud along the link of the anti-rotation element.
9
f Check that the switching ring can be moved easily in the sleeve.
The unit that is moved must not catch or run jerkily.
If this is not the case after greasing, send the sleeve to SIPLACE Sleeve Maintenance.