SIPLA CE D1 / D2 8 Annual maintenance work 02/2010 EN Edition 71 Check the hood switch and the emergency-stop button 8 : Make sur e that the placem ent syste m is switched on and the opera ting syst em has started up. : …

100%1 / 86
8 Annual maintenance work SIPLACE D1 / D2
02/2010 EN Edition
70
8
SIPLACE D1 / D2 8 Annual maintenance work
02/2010 EN Edition
71
Check the hood switch and the emergency-stop button 8
: Make sure that the placement system is switched on and the operating system has started up.
: Make sure that "Control on" is set on the placement machine.
You can tell this from the main fault indicator.
Press the Start button.
8
a Open a protective cover. The other protective cover(s) must be closed.
The control must drop out immediately. You will hear this clearly by the venting compressed air.
s Move the gantry in the X and Y directions.
It must move effortlessly and without resistance.
: If the control does not switch off or the gantry does not move effortlessly, then the hood switch
may be defective. Replace it with a new switch and check the functions again.
: Test all the protective covers individually and move the associated gantry.
8
d Check the hood switch for damage, particularly the plastic web in the middle.
If there is any damage, replace the hood switch with a new one.
: Check that the actuator moves cleanly and effortlessly into the switching unit.
If this is not the case, align the actuator and switching unit with respect to one another.
8
f Check the emergency-stop button for damage.
: Check that the control switches off immediately when you actuate the button.
Replace the button with a new one if this is not the case.
8
8
8