2 Overview 2.4 Requirements and restrictions 16 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017

2 Overview
2.4 Requirements and restrictions
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 15
2.4 Requirements and restrictions
●
The LDU‑X can be used on SIPLACE X, SX and DX series machines.
●
The LDU‑X can only be set up on X tables. You can not configure the LDU-X on S tables.
●
The LDU-X can handle components up to a maximum size of 42x42 mm.
– X4i: If a WPC is used the maximum component size is 32x32 mm.
– SX1 and SX2: If the outer table position is used - depending on the head configuration -
there may be restrictions regarding the size of the components handled.
●
The LDU‑X requires station software version 604 or higher to operate on SIPLACE placement
machines.
●
The following restrictions are valid for the placement heads:
– SW 604 and 605: only C&P6, C&P12 and TwinHead
– from SW 703: no restrictions
●
The LDU‑X requires line computer software SIPLACE Pro version 5.0.1.35 and higher to op-
erate on SIPLACE placement machines.
●
The LDU‑X must be manually configured in the setup.
●
The LDU-X must not allocate the outer 6 tracks in each case (right and left).
●
You can only configure one LDU-X per table.
●
Do not set up any linear feeder modules directly next to the LDU-X.
●
Feeders with small components should not be set up directly next to the LDU-X.
●
The manual tray can not be set up on the same table as an LDU-X.
●
MTC and LDU-X units can only be set up opposite one another in single gantry machines.
●
The placement performance of the machine is limited by the dip process.
●
When dipping components, no placement data will be generated for operator information (OIS
or Ma-DaMaS).
●
A gantry can only operate with one LDU‑X (even if pickup can be performed from two place-
ment locations).
●
Only one LDU-X can be used for machines with one gantry in the placement area.
●
The LDU‑X can be operated outside the machine with the help of an SSE (Single Slot EDIF).
●
In case of SW 703 with SX there may be restrictions regarding the component size.
Hardware function status of LDU-X [03063461-xx]
Function
status
Explanation
FS1 The level sensor and refill unit can not be accommodated in this version.
FS2 In this version, the basic module is fitted 1.5 mm lower, to prevent the risk of
collisions between the level sensor and the placement head.
Software version 2.00 or higher is required to operate the level sensor.
FS3 The FS3 version has two additional sensors for detecting the dip plate and the
dip tray. This version is mandatory for the operation of the refill unit.
Software version 2.00 or higher is required for evaluation of the plate and tray
sensors, the level sensor and operation of the refill unit.

2 Overview
2.4 Requirements and restrictions
16 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017

3 Hardware Description
3.1 Controls
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 17
3 Hardware Description
3.1 Controls
1. Control panel on the upper side
2. Flap for refill unit
3. Handle
4. Warning instructions
5. EMERGENCY STOP button
6. Service switch
3.2 Operator panel
1. Display (4 lines, each with 20 char-
acters)
2. LED for refill unit *
3. ENTER button
4. ESC button
5. SELECT UP button
6. SELECT DOWN button
7. VALUE button + (plus)
8. VALUE button – (minus)
9. Green status lamp
10. Yellow status lamp
11. Amber status lamp
12. Red status lamp
*Only present if the LDU-X is fitted with a
refill unit.