4 Software Description 4.3 Menu Description Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 41 ► Press the hose into the clamps at the 3 points shown in the diagram. ► Press the ENTER button. The LDU-X display…

4 Software Description
4.3 Menu Description
40 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
► Insert the cartridge first at the top(1) and
then at the bottom(2).
► (1) Close the hose clamp.
► (2) Make sure that the fixture engages
properly.
► (1) Thread the hose from behind through
the hose duct (towards the front).
► (2) Press the rest of the hose behind the
side panel.
► Clamp the hose onto the flux tank.
The hose should protrude by approx. 0.5
cm into the flux tank.

4 Software Description
4.3 Menu Description
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 41
► Press the hose into the clamps at the 3
points shown in the diagram.
► Press the ENTER button.
The LDU-X display will show the following message:
► (1) Check again whether the rubber plug
has been inserted correctly into the cart-
ridge.
► (2) Check again whether the hose clamp
fixture has engaged properly.
► Close the cover.
► Close the service lid.
► Press the ENTER button.

4 Software Description
4.3 Menu Description
42 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
The LDU-X display will show the following message:
The LDU-X will now begin filling. The flux is pressed into the hose and coated alternately, until the
set flux level has been reached.
Once the set level of flux has been reached, the LDU-X automatically performs the function WARM UP.
WARM UP function
With the help of this warm up function, the flux in the LDU‑X can be prepared so that it is ready for
operation. This performs a set number of single cycles in succession until the defined warm up time
has expired. This movement "warms up" the flux.
INITIALIZATION function
With the initialization function, the LDU‑X can be brought into a defined basic position. If initializa-
tion is performed successfully, you can assume that the electrical and mechanical functions of the
LDU-X are OK.
Initialization procedure
The axes can have any initial starting position. Firstly, the Z axis (dip plate) is moved down to the Z
sensor. After this, the X axis (flux tank) is moved to the X init sensor in the basic position.