3 Hardware Description 3.3 Status Indicator 18 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 3.3 Status Indicator LED LDU‑X state All LEDs LDU‑X is installed Green LDU-X is ready Green + red Coating command …

3 Hardware Description
3.1 Controls
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 17
3 Hardware Description
3.1 Controls
1. Control panel on the upper side
2. Flap for refill unit
3. Handle
4. Warning instructions
5. EMERGENCY STOP button
6. Service switch
3.2 Operator panel
1. Display (4 lines, each with 20 char-
acters)
2. LED for refill unit *
3. ENTER button
4. ESC button
5. SELECT UP button
6. SELECT DOWN button
7. VALUE button + (plus)
8. VALUE button – (minus)
9. Green status lamp
10. Yellow status lamp
11. Amber status lamp
12. Red status lamp
*Only present if the LDU-X is fitted with a
refill unit.

3 Hardware Description
3.3 Status Indicator
18 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
3.3 Status Indicator
LED LDU‑X state
All LEDs LDU‑X is installed
Green LDU-X is ready
Green + red Coating command
Yellow Service mode
Amber Warning that the LDU-X will soon switch over to "Not Ready"
(e.g. not enough flux, maintenance required)
Coating is still being performed and dipping is still possible.
Red LDU‑X is not ready for operation (e.g. error, no flux)
Dipping is no longer possible.
LED for refill unit
Off No message
Flashes Warning that the LDU-X will soon switch over to "Not Ready"
(as above at "amber")
Continuous light LDU‑X is not ready for operation
(as above, under "red")
3.4 LDU‑X design
1. Dip plate with cavity
2. Flux tank
3. Level sensor (option)
4. Cover (only for function states 1 and 2)
5. Lock for flux tank
6. Downholder

3 Hardware Description
3.4 LDU‑X design
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 19
3.4.1 Energy and data transfer
The adapter is equipped with an EDIF (Energy and Data Interface).
The adapter uses a non-contact system for the electrical transmission of energy and communica-
tion of data. This makes it possible to place the adapter on the changeover table or to remove it,
without connecting any additional cables.
Energy transmission
The energy is transmitted with the help of a split transformer. One half of the transformer is located
in the frame of the FCU, while the other half is in the adapter. If the adapter is placed on the
changeover table, the two halves will be exactly opposite one another. The floating state of the
EDIF in the adapter ensures that the two sections of the transformer can be firmly connected to
one another without gaps.
1. EDIF for FCU
2. EDIF for adapter
3. Coil for FCU (primary side)
4. Coil for adapter (secondary side)
5. Split transformer ferrite core
Both transformer sections have coils. A.C. voltage from the machine side induces a magnetic field
in the transformer core, which then generates a.c. voltage on the adapter side. This power is used
to supply the control unit and drives for the feeder modules.
Data transmission
The communication between placement machine and adapter is also realized without contact. The
data is transmitted with the help of infrared (IR) light, through light conductors. Two channels are
used for this: one for the signals from the FCU to the adapter and one for the signals from the ad-
apter to the FCU.
Each channel has a transmitter (IR diode) and a receiver (IR photo element).
The signals transmitted are, for example, commands for feeder track cycles, error messages and
signals from the feeder module. The volume of commands depends greatly on the type of feeder
module connected.
1. EDIF for FCU
2. EDIF for adapter
3. IR transmitter
4. IR receiver
5. Light conductor