00196749-02_UM_LDU-X_EN.pdf - 第37页
4 Software Description 4.3 Menu Description Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 37 The LDU-X display will show the following message: ► Insert the dip plate. Make sure that the dip plate engages a…

4 Software Description
4.3 Menu Description
36 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
FITTING SYSTEM function
This function is used to fit the cleaned dipping components into the LDU-X.
The squeegee moves right to the front, so that the park plate and the dip tray can be easily fitted.
The LDU-X display will show the following message:
► Lift the level sensor (1).
Make sure that you do not dirty the level
sensor during this.
► Insert the dip tray (2) as shown, with the
recess on the left-hand side.
► Insert the park plate (1)as shown.
Make sure that the park plate engages
audibly.
► Lower the level sensor (2).
When fully fitted, the park plate covers approx.
half of the dip tray.
► Press the ENTER button.
The squeegee moves back into the park position, so that the dip plate can be easily fitted.

4 Software Description
4.3 Menu Description
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 37
The LDU-X display will show the following message:
► Insert the dip plate.
Make sure that the dip plate engages aud-
ibly.
► Press the ENTER button.
The squeegee moves onto the dip plate.
The LDU-X display will show the following message:
► Make sure that the lock (1) is on the right,
in the OPEN position.
► Swing the downholder up (2).
► Fit the flux tank.
Make sure that the three pins (3) are visible
on the right-hand side of the flux tank.

4 Software Description
4.3 Menu Description
38 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
► Lower the downholder (1).
► Make sure that the pins on the side of the
flux tank (2) engage with the downholder.
► Press the lock.
► Push the lock (3) to the left, into the
CLOSED position.
► Press the ENTER button.
Only for LDU-X with refill unit
► Insert the hose attachment onto the squee-
gee, with the openings over the two pins.
► Press the hose attachment into place.
Continue with the functions FIRST FILLING or REFILL FLUX.