3 Hardware Description 3.4 LDU‑X design 20 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017

3 Hardware Description
3.4 LDU‑X design
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 19
3.4.1 Energy and data transfer
The adapter is equipped with an EDIF (Energy and Data Interface).
The adapter uses a non-contact system for the electrical transmission of energy and communica-
tion of data. This makes it possible to place the adapter on the changeover table or to remove it,
without connecting any additional cables.
Energy transmission
The energy is transmitted with the help of a split transformer. One half of the transformer is located
in the frame of the FCU, while the other half is in the adapter. If the adapter is placed on the
changeover table, the two halves will be exactly opposite one another. The floating state of the
EDIF in the adapter ensures that the two sections of the transformer can be firmly connected to
one another without gaps.
1. EDIF for FCU
2. EDIF for adapter
3. Coil for FCU (primary side)
4. Coil for adapter (secondary side)
5. Split transformer ferrite core
Both transformer sections have coils. A.C. voltage from the machine side induces a magnetic field
in the transformer core, which then generates a.c. voltage on the adapter side. This power is used
to supply the control unit and drives for the feeder modules.
Data transmission
The communication between placement machine and adapter is also realized without contact. The
data is transmitted with the help of infrared (IR) light, through light conductors. Two channels are
used for this: one for the signals from the FCU to the adapter and one for the signals from the ad-
apter to the FCU.
Each channel has a transmitter (IR diode) and a receiver (IR photo element).
The signals transmitted are, for example, commands for feeder track cycles, error messages and
signals from the feeder module. The volume of commands depends greatly on the type of feeder
module connected.
1. EDIF for FCU
2. EDIF for adapter
3. IR transmitter
4. IR receiver
5. Light conductor

3 Hardware Description
3.4 LDU‑X design
20 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017

4 Software Description
4.1 Operating Modes
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 21
4 Software Description
The following section describes the LDU‑X software. This software can be displayed in German or
English.
4.1 Operating Modes
The LDU‑X can be run in two operating modes. In production mode, you can control all the produc-
tion-related processes. Service mode gives you access to all the LDU-X parameters. With the help
of the key switch, you can change over between modes.
The service mode is subdivided into standard and advanced service mode. The advanced service
mode is password protected and is only intended for appropriately trained personnel or service
technicians.
If the key switch points vertically to SERVICE, the service menu will be shown on the display.
If the key switch points horizontally to PRODUCTION, the production menu will be shown on the
display.