7 Options 7.1 Level sensor Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 69 ► Refit the dip plate. ► Run the cables as shown in the diagram. ► Fix the middle cover into place with the three screws. ► Fit the…

100%1 / 100
7 Options
7.1 Level sensor
68 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
7.1.1.4 Adjusting the control unit
The control unit has been factory adjusted but will need to be checked and possibly corrected, due
to the different reflection properties of the park plates.
► Note the measurement value shown for the control unit when the bar is swung down =
value_ON
► Note the measurement value when the bar is swung up = value_OFF
► Calculate the switching threshold = (value_ON - value_OFF) *0.2 + value_OFF
► Check the switching threshold by slowing swinging up the sensor bar.
The yellow LED for the control unit is initially switched to "on". Once the switching threshold is
reached, the LED will switch to "off". The measurement value shown at this point must correspond
to the calculated switching threshold.
If the values differentiate by more than +/-20 digits from one another, you will need to reset the
switching threshold, as described in the instructions provided. The following settings are otherwise
required:
nonc = nc
FSEt = Stnd
dlay = off
7.1.1.5 Closing the LDU-X
► Push the slide unit forwards.
► Refit the park plate.
► Push the slide unit back.
Inserting the coating jar:
► (1) Lift the downholder.
► (2) Insert the coating jar and lower the
downholder again.
► (3) Push the lock on the downholder to the
position CLOSED.
7 Options
7.1 Level sensor
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 69
► Refit the dip plate.
► Run the cables as shown in the diagram.
► Fix the middle cover into place with the
three screws.
► Fit the top cover into place.
7.1.1.6 Initializing the LDU-X (storing sensor position)
After assembly, the LDU-X needs to "learn" the control position for the level sensor.
► On the LDU-X display, open the Service menu and select the function SYSTEM FUNCTION /
LEVEL SENSOR ADJUSTMENT. The coating head will be moved forwards, until the correct
position is found.
7.1.1.7 Function Test
After initialization, check whether the LDU-X works properly.
► Connect the LDU-X to a single slot EDIF or to a changeover table at the machine.
► On the LDU-X display, open the Service menu and select the function PRODUCTION PARA-
METERS / LEVEL SENSOR ON.
► Select the function SERVICE FUNCTIONS / SINGLE CYCLE.
If an error occurs when calling up this function, correct it as described in the User Manual for the
LDU-X.
7 Options
7.1 Level sensor
70 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
7.1.2 Activating and deactivating the level sensor
Perform the following steps to enable or disable the level sensor:
► Set the key switch to the position SERVICE (vertical).
► On the LDU-X display, select the PRODUCT PARAMETERS menu.
► Press the ENTER button.
► Select the function LEVEL SENSOR.
► Press the VALUE button (+), until the display shows the state ON (enabled) or OFF (dis-
abled).
► Press the ENTER button to save the value.
7.1.3 Function
The level sensor works with a light beam which scans the edge of the flux shaft.
To detect contamination, a control measurement of the park plate is performed when the tank is
over the dip plate and another control measurement is performed over the slanted part of the tank.
Another control measurement will be performed over the slanted part of the tank. If these measure-
ments are not successful, the LDU-X will stop and a corresponding error message will be shown.
CAUTION
Do not dismantle the sensor.
The sensor is factory set and may not be taken apart.
If the flux sinks below a certain level, this is recognized by the level sensor. The minimum flux level
at which the sensor will trigger can be set via the PRODUCT PARAMETERS menu.
Once the sensor has detected a level of flux which is too low, the top red LED on the right of the
display will shine and the display will show the following message:
However, the LDU-X will not stop.
The remaining cycles set for the LDU-X will now be processed.
After completion of the remaining cycles, the LDU-X will stop and the display will show the following
message.
The level sensor performs a control measurement.
If the level sensor is dirty or not fitted correctly, the following message will be shown on the display
of the LDU-X:
An error message will also be shown on the SIPLACE placement machine.
If the message FLUX LEVEL LOW is shown on the display, the flux now needs to be filled up
again and the error messages on the placement machine and the LDU-X need to be acknow-
ledged.