5 Working with the LDU‑X 5.2 Configuring the LDU‑X 54 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 If a value is shown in red, this means that the deviation exceeds the predefined threshold: The dip area is…

100%1 / 100
5 Working with the LDU‑X
5.2 Configuring the LDU‑X
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 53
Aligning the placement machine
The measurement run sets the dip plate parallel to the gantry. It does NOT determine the level of
the dip plate compared to the ground. It is therefore important that the machine in which the LDU‑X
is used is standing absolutely level. If the machine is not level and the dip plate is then aligned par-
allel to the gantry, the dip plate will then not be level in relation to the ground. The flux might run out
of the cavity in this case.
► Make sure that the placement machine is level.
► Check the levelness in the conveyor area with an accurate spirit level.
5.2.5.1 Performing Height Measurement
► In the LDU‑X basic view in SIPLACE Pro, select the Check Planarity button...
The Check Planarity dialog box will appear.
► Check whether the cavity is free of flux.
► Confirm the clean state of the cavity by enabling the Dipping Area Clean checkbox. The
Measurement button will become active.
► Check whether there is a nozzle on the placement head.
► Click on the Measurement button to begin measurement. The machine will automatically per-
form the measurement and then show the values determined in the Measuring Height field.
► Read the values. If the relative values for measuring points 2 and 3 are lower than +/- 50 µm,
the LDU‑X is set correctly.
► If the values are greater than +/- 50 µm, adjust the adjusting screws on the LDU‑X accord-
ingly, to align the dip plate (see next section).
5 Working with the LDU‑X
5.2 Configuring the LDU‑X
54 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
If a value is shown in red, this means that the deviation exceeds the predefined threshold: The dip
area is not level.
Measurement procedure
The placement head moves over the first measuring point in the cavity of the dip plate. After this,
the Z-axis moves slowly downwards until the nozzle springs into place and the Z-axis sensor re-
ports that the nozzle is now down on the dip plate. The Z-axis then moves up again. The system
calculates the absolute height of the first measuring point.
The gantry now moves to the second measuring point. The Z-axis performs height measurement
again and now determines the relative height difference to the first measuring point. If the measure-
ment for the second measuring point is positive, measuring point 2 is higher than measuring point
1. If it is negative, this means that it is lower. If the relative measurement is zero, this means that
both measuring points are at the same height. The same procedure is applied to the third measur-
ing point.
Explanation of display
Measuring point 1 = reference point
Absolute height in µm = the measured height of the respective measuring point.
Relative height in µm = the deviation of the absolute height of measuring point 2 or 3 to the refer-
ence point. This value is always 0 for the reference point (measuring point 1).
5.2.5.2 Aligning the dip plate
Tools required:
●
Long, straight Allen key 3 mm
●
Fork wrench, 9 mm
The complete application unit is positioned on the adapter base plate with three contact points.
One point is fixed. It has an inserted steel ball. The other two contact points can be adjusted.
These contact points are shown below in the example of an LDU-X without covers.
To access the adjustment screws for the contact points when the LDU-X is installed and fully as-
sembled, there are openings on the right and left of the side panels.
5 Working with the LDU‑X
5.2 Configuring the LDU‑X
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 55
Use a 9 mm fork wrench to adjust the adjustment screw through the opening in the side cover. The
Allen screw can be accessed from above, through the LDU-X.
Adjustment screw
1. Allen screw M4
2. Spring washers (4 x)
3. Adjustment screw with fine thread
4. Base plate of application unit
5. Threaded hole of clamping screw
6. Contact surface
7. Adapter base plate
Adjustment screw function
The adjustment screws must have no play in the threaded hole of the base plate. The threaded
holes are therefore slit and pretensioned with the clamping screw. These clamping screws are set
correctly at the factory and are secured with locking varnish (Loctite). You do not need to loosen
the clamping screws, when adjusting the dip plate.
The long Allen screw (M4) presses the adjustment screw onto the contact surface of the adapter
base plate, via the spring assembly. The spring assembly must always be tensioned. This ensures
that the two base plates keep the set distance once it has been defined.