00196749-02_UM_LDU-X_EN.pdf - 第65页
7 Options 7.1 Level sensor Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 65 7.1.1.2 Installing the level sensor NOTICE The level sensor is preset at the factory. Do not change these settings. ► Fasten the an…

7 Options
7.1 Level sensor
64 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
Remove the coating jar:
► (1) Move the catch of the downholder to
the OPEN position.
► (2) Lift the downholder.
► (3) Remove the coating jar and lower the
downholder again.
► Push the slide unit forwards.
► Remove the park plate.
Remove the side cover plates:
► Place the LDU-X down on its right-hand
side, on a soft and stable surface.
► Loosen the 6 screws marked in the dia-
gram.
► Lift up the left cover plate.
► Place the LDU-X down on its left-hand
side, on a soft and stable surface.
► Loosen the 6 screws (same as for left
cover plate).
► Lift up the right cover plate.
Remove the middle cover:
► Stand the LDU-X up again.
► Loosen the 3 screws marked in the dia-
gram.

7 Options
7.1 Level sensor
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 65
7.1.1.2 Installing the level sensor
NOTICE
The level sensor is preset at the factory. Do not change these settings.
► Fasten the angle fixture bracket with two
screws to the position shown in the dia-
gram.
► Fasten the level sensor with two screws to
the position shown in the diagram.
CAUTION!
Make sure that the level sensor is aligned
straight on the slide.
.
Connecting the fiber optic cable to the control
unit:
► Connect the marked cable to the top con-
nection.
► Connect the other cable to the bottom con-
nection.
► Lock the control unit into place.
► Run the cable as shown in the diagram.
► Screw the control unit to the angle fixture
bracket with two screws.

7 Options
7.1 Level sensor
66 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
► Loose the LDU-X base unit from the X ad-
apter (2 screws).
► Lift the LDU-X base unit to one side.
NOTICE!
Connect the control unit cable to the
terminal strip:
Observe the safety instructions in the ESD
guidelines.
.
► Press the terminal in.
► Plug in the cable.
► Let the terminal go.
► Lift the LDU-X base unit back onto the X
adapter.