8 Process Technology 8.8 Dipping Parameters in SIPLACE Pro Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 93 8.8 Dipping Parameters in SIPLACE Pro The two procedures Dipping-Vision and Vision–Dipping plus the…

8 Process Technology
8.7 Dipping Procedure for C&P Head
92 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
(4) Segment 1 dips the first component into the cavity of the LDU-X.The head then moves the seg-
ments on and dips the next components into the cavity, in succession.
(5) Segment 1 is now under the component camera which is measuring the first component.
(6) Segment 1 is now in the turning station.The turning station rotates the component into the
placement angle.
(7) Segment 12 has just dipped the last component into the LDU-X cavity. The gantry now moves
from the LDU-X to the board in the board conveyor.
(8) Segment 1 places the first component. At the same time, segment 7 is measured by the camera
and segment 5 is rotated into the placement angle. The head then moves the segments on and
places the next components in succession.
(9) The turning station rotates the empty segments back into the pickup angle.

8 Process Technology
8.8 Dipping Parameters in SIPLACE Pro
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 93
8.8 Dipping Parameters in SIPLACE Pro
The two procedures Dipping-Vision and Vision–Dipping plus the dwell time can be selected in
SIPLACE Pro. The parameters for the dipping process can be set in the Component Shape Editor,
at Handling (1) in the Dip (2) section.
Selection list Mode:
●
No dipping
●
Dipping/Vision
●
Vision/Dipping
Entry field Dwell time [ms]: the dwell time in milliseconds can be set here.
Checkbox Inspect flux after dipping: this option enables an additional control function. The
component is moved past the component camera again after dipping. This checks whether the
component was displaced during dipping.
8.9 Vacuum checks
During the placement process, the vacuum checks test whether the component is on the nozzle or
whether it might have been lost in the flux.
●
Vacuum check before dipping
●
Vacuum check after dipping
If the component was lost, it will be placed again.
8.10 Pressing Down Dipped Components
It might be useful to hold the components on the board or to press them against the board for a
short moment during placement.
For this purpose, go to the submenu Handling(1) in the Component Shape Editor , where you can
set a Waiting time(2) in milliseconds (typically: 100ms):

8 Process Technology
8.11 Cicatrization time
94 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
8.11 Cicatrization time
Flux can consist of several different components. These are typically:
●
Colophony or resin (solderability, adhesive force, cleanliness, pressure application)
●
Activator (solderability, reliability, product life, cleanliness)
●
Stabilizer (thixotropic stability, pressure application, contour stability)
●
Solvent (resistance behavior, adhesive force, viscosity)
The solvent in flux is water or alcohol based. These substances evaporate with time if the flux is
kept in an open tank.
The LDU-X has a very thin layer or flux in the dip plate cavity. This means that the solvent can
evaporate over a large surface (1). A thin skin then forms on the surface of the flux (2). Inside this
skin, the process properties of the flux differ from those in the remaining flux.
If you can reckon with longer standstill (inactive) times during the production run, you can set a ci-
catrization time in SIPLACE Pro. The LDU-X will then perform an application run after this period
has expired.
► In SIPLACE PRO, switch over to the Pro-
cess material(1)view .
► Doubleclick on DefaultDipFluxMater-
ial(2)in the tree structure.
► Go to the Dip flux parameters and specify
a cicatrization time and a curing time for
the flux used. For details, consult the data
sheet for your flux.