00196749-02_UM_LDU-X_EN.pdf - 第85页

8 Process Technology 8.4 Layer thickness Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 85 Since the value of 2/3 is a rough estimate, the exact amount of flux which stays on the component must be determined …

100%1 / 100
8 Process Technology
8.4 Layer thickness
84 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
In the following diagram, the same component is dipped into various different dip plates. The dip
plate cavity in (1) is deeper than in (2). This means that more flux stays on the component because
the layer of flux is thicker here.
Influence of coating fluid on the layer thickness
The capillary effect describes the behavior of fluid as shown during the contact between solids and
capillaries e.g. narrow tubes, gaps or hollow spaces.
Example: if one dips a glass tube vertically into water, the water will rise up a little in the narrow
glass tube against the force of gravity. This effect is caused by the surface tension of the fluid itself
and the interfacial tension of the fluids with the solid surface.
1. Dip plate
2. Flux
3. Hollow
4. Cavity depth in the dip plate
5. Remaining flux height
Multiple measurements lead to a value for reduction of the layer thickness. This value shows that
the flux layer thickness is roughly 2/3 of the cavity depth i.e. the layer thickness is reduced by about
1/3. The following table lists the dip plates for the LDU‑X with the cavity depth and the resulting
layer thickness.
Item number Cavity depth [µm] Layer thickness [µm]
03059408-xx Blank part -
03063053-xx 20 ~ 13
03063054-xx 30 ~ 20
03063055-xx 40 ~ 26
03063056-xx 50 ~ 33
03063057-xx 60 ~ 40
03063058-xx 70 ~ 46
03063059-xx 80 ~ 53
03063060-xx 90 ~ 60
03063061-xx 100 ~66
03063106-xx 360 ~ 240
8 Process Technology
8.4 Layer thickness
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 85
Since the value of 2/3 is a rough estimate, the exact amount of flux which stays on the component
must be determined in tests. In very critical processes, dip plates with a customized cavity depth
can be supplied.
Influence of coating fluid on the dipping area
A hollow is formed in the flux at the edge of the cavity. This has a width of about one to two milli-
meters.
1. Dip plate
2. Flux
3. Width of hollow
This means that the dip plate area which can be used is smaller than the cavity itself.
1. Dip plate
2. Cavity
3. Hollow
4. Dipping area, determined by the hollow
5. Edge area, determined by the hollow
This effect is taken into account in the station software. The placement machine automatically
keeps an edge of 3 mm when dipping components. The dipping area is therefore 6 mm smaller
than the cavity itself. The cavity has a size of 75 mm x 55 mm, the available dipping area only a
size of 69 mm x 49 mm.
1. Dip plate
2. Cavity
3. Print of dipped component in the flux
4. Dipping area, determined by the software
5. 3 mm edge area, determined by the soft-
ware
8 Process Technology
8.5 Parameters for the application process
86 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
8.5 Parameters for the application process
Application procedure
1. The flux tank moves at maximum X-axis speed into the reverse position (5).
2. The flux tank is now in reverse position (8).
3. The flux tank moves with set X-axis application speed (6) over the cavity and into the acceler-
ation position(9).
4. The flux tank moves at maximum X-axis speed (7) into the park position(10).
Application speed
The speed with which the flux tank moves over the cavity can be set in the menu PRODUCT
PARAMETER / SPEED.
This parameter has a great influence on the surface of the flux after application
The optimum speed for the medium used needs to be determined in tests. It is therefore useful to
use the following standard speeds as a starting point:
●
Flux = 250
●