7 Options
7.2 Refill Unit
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 75
► Pull the flat ribbon cable for the refill unit
into the LDU-X frame.
► Push the refill unit from behind, into the
LDU_X frame.
 CAUTION!
Make sure that you can see the holes for
the refill unit screws through the holes in
the frame.
.
► Loosely fasten the refill unit with 2 screws,
so that the refill unit can still be moved.
► Align the refill unit straight on the frame.
 CAUTION!
Make sure that the flap can still be closed.
.
► Once the refill unit is in the correct posi-
tion, tighten the two screws.
► Fix the cable into place with a cable tie, as
shown in the diagram, so that the cable is
not trapped, causing the refill unit to jam.
7 Options
7.2 Refill Unit
76 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
► Push the lower cover plate onto the LDU-
X.
Screwing the lower cover plate into place:
► Fasten the 5 screws marked in the dia-
gram.
► Turn the LDU-X onto its other side.
► Fasten the sixth screw.
► Run the cable behind the plate.
► Screw the plate to the refill unit.
► Stand the LDU-X upright again.
► Loosen the LDU-X base unit.
7 Options
7.2 Refill Unit
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 77
► Lift the LDU base unit to one side.
► Connect the diode cable to the terminal
strip.
●
Red to position K12
●
Black to position K13
 NOTICE!
Observe the safety instructions in the ESD
guidelines.
.
●
Press the terminal in.
●
Plug-in the cable.
●
Let the terminal go.
► Lift the LDU-X base unit to the other side.
► Press the connector of the flat ribbon cable
from above, onto the marked free socket.
 CAUTION!
Make sure that the connector has been
completely pressed into place.
.