5 Working with the LDU‑X
5.2 Configuring the LDU‑X
52 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
5.2.4 Removing the LDU‑X
There are two ways to remove the adapter from the placement machine:
1. Feeder module logout via the GUI.
► (1) Log the LDU-X out of the station computer via the user interface.
ð The FCU opens the mechanical lock.
► (2) Pull the LDU-X out.
► (3) Remove the LDU-X from the changeover table.
NOTICE
If the LDU‑X is not removed from the changeover table within approx. 8 seconds, the lock
will engage again and it will be logged back on at the placement machine.
2. Remove the LDU‑X manually from the changeover table.
If the placement machine is switched off or communication with the FCU is not possible, the
LDU_X can also be removed manually.
► Move the changeover table from the placement machine.
► Manually open the lock at the head end.
► Pull the LDU-X out.
► Remove the LDU-X from the changeover table.
5.2.5 Setting up the LDU-X
Information
To ensure that the components can be dipped into the medium over the entire dipping area, it is
important that the dipping area is not tilted. You therefore need to align the LDU-X parallel to the
gantry or to the placement head of the placement machine. The LDU‑X has two adjustment screws
for this purpose. The correct position of the cavity can be checked with the help of the measure-
ment run in the station software.

5 Working with the LDU‑X
5.2 Configuring the LDU‑X
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 53
Aligning the placement machine
The measurement run sets the dip plate parallel to the gantry. It does NOT determine the level of
the dip plate compared to the ground. It is therefore important that the machine in which the LDU‑X
is used is standing absolutely level. If the machine is not level and the dip plate is then aligned par-
allel to the gantry, the dip plate will then not be level in relation to the ground. The flux might run out
of the cavity in this case.
► Make sure that the placement machine is level.
► Check the levelness in the conveyor area with an accurate spirit level.
5.2.5.1 Performing Height Measurement
► In the LDU‑X basic view in SIPLACE Pro, select the Check Planarity button...
The Check Planarity dialog box will appear.
► Check whether the cavity is free of flux.
► Confirm the clean state of the cavity by enabling the Dipping Area Clean checkbox. The
Measurement button will become active.
► Check whether there is a nozzle on the placement head.
► Click on the Measurement button to begin measurement. The machine will automatically per-
form the measurement and then show the values determined in the Measuring Height field.
► Read the values. If the relative values for measuring points 2 and 3 are lower than +/- 50 µm,
the LDU‑X is set correctly.
► If the values are greater than +/- 50 µm, adjust the adjusting screws on the LDU‑X accord-
ingly, to align the dip plate (see next section).

5 Working with the LDU‑X
5.2 Configuring the LDU‑X
54 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
If a value is shown in red, this means that the deviation exceeds the predefined threshold: The dip
area is not level.
Measurement procedure
The placement head moves over the first measuring point in the cavity of the dip plate. After this,
the Z-axis moves slowly downwards until the nozzle springs into place and the Z-axis sensor re-
ports that the nozzle is now down on the dip plate. The Z-axis then moves up again. The system
calculates the absolute height of the first measuring point.
The gantry now moves to the second measuring point. The Z-axis performs height measurement
again and now determines the relative height difference to the first measuring point. If the measure-
ment for the second measuring point is positive, measuring point 2 is higher than measuring point
1. If it is negative, this means that it is lower. If the relative measurement is zero, this means that
both measuring points are at the same height. The same procedure is applied to the third measur-
ing point.
Explanation of display
Measuring point 1 = reference point
Absolute height in µm = the measured height of the respective measuring point.
Relative height in µm = the deviation of the absolute height of measuring point 2 or 3 to the refer-
ence point. This value is always 0 for the reference point (measuring point 1).
5.2.5.2 Aligning the dip plate
Tools required:
●
Long, straight Allen key 3 mm
●
Fork wrench, 9 mm
The complete application unit is positioned on the adapter base plate with three contact points.
One point is fixed. It has an inserted steel ball. The other two contact points can be adjusted.
These contact points are shown below in the example of an LDU-X without covers.
To access the adjustment screws for the contact points when the LDU-X is installed and fully as-
sembled, there are openings on the right and left of the side panels.