00196749-02_UM_LDU-X_EN.pdf - 第28页
4 Software Description 4.3 Menu Description 28 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 ► (1) Hold the hose at the front, on the cart- ridge. ► (2) Insert the rubber plug as far as possible into the car…

4 Software Description
4.3 Menu Description
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 27
► Open the fixture on the hose clamp.
► Lift the cartridge out.
► Pull the hose off the tube.
► Place the tube in the cleaning tub.
► (1) Twist the top off the new cartridge.
► (2) Insert one end of the hose as far as
possible onto the cartridge.

4 Software Description
4.3 Menu Description
28 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
► (1) Hold the hose at the front, on the cart-
ridge.
► (2) Insert the rubber plug as far as possible
into the cartridge. Make sure that no air
pockets are formed in the cartridge.
► Insert the cartridge first at the top(1) and
then at the bottom(2).
► (1) Close the hose clamp.
► (2) Make sure that the fixture engages
properly.
► Press the hose behind the side panel.
► Press the ENTER button.

4 Software Description
4.3 Menu Description
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 29
The LDU-X display will show the following message:
► (1) Check again whether the rubber plug
has been inserted correctly into the cart-
ridge.
► (2) Check again whether the hose clamp
fixture has engaged properly.
► Close the cover.
► Close the service lid.
► Press the ENTER button.
The LDU-X display will show the following message:
The LDU-X will now begin filling. The flux is pressed into the hose and coated alternately, until the
set flux level has been reached.
Once the set level of flux has been reached, the LDU-X automatically performs the function WARM
UP.