7 Options
7.1 Level sensor
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 65
7.1.1.2 Installing the level sensor
NOTICE
The level sensor is preset at the factory. Do not change these settings.
► Fasten the angle fixture bracket with two
screws to the position shown in the dia-
gram.
► Fasten the level sensor with two screws to
the position shown in the diagram.
 CAUTION!
Make sure that the level sensor is aligned
straight on the slide.
.
Connecting the fiber optic cable to the control
unit:
► Connect the marked cable to the top con-
nection.
► Connect the other cable to the bottom con-
nection.
► Lock the control unit into place.
► Run the cable as shown in the diagram.
► Screw the control unit to the angle fixture
bracket with two screws.
7 Options
7.1 Level sensor
66 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
► Loose the LDU-X base unit from the X ad-
apter (2 screws).
► Lift the LDU-X base unit to one side.
 NOTICE!
Connect the control unit cable to the
terminal strip:
Observe the safety instructions in the ESD
guidelines.
.
► Press the terminal in.
► Plug in the cable.
► Let the terminal go.
► Lift the LDU-X base unit back onto the X
adapter.
7 Options
7.1 Level sensor
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 67
► Screw the LDU-X base unit to the X ad-
apter.
Fastening the side cover plates:
► Place the LDU-X down on its right-hand
side, on a soft and stable surface.
► Place the left cover plate the right way
onto the LDU-X.
► Fix with the 6 screws.
► Place the LDU-X down on its left-hand
side, on a soft and stable surface.
► Place the right cover plate the right way
onto the LDU-X.
► Fix with the 6 screws.
7.1.1.3 Checking the Light Conductor
► Connect the LDU-X to a power source.
This can be:
●
a Single Slot EDIF
●
the changeover table of the machine
► Check the light point below the level
sensor
●
Correct (left):
the light point shows a completely filled
shape.
●
Wrong (right):
the light point shows a light crown only.
If only a light crown can be seen, the light conductors are interchanged and have to be connected
properly to the control unit.
If no light point can be seen, the cables are not properly connected to the control unit. This has to
be corrected.