00196749-02_UM_LDU-X_EN.pdf - 第50页

5 Working with the LDU‑X 5.2 Configuring the LDU‑X 50 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 Setup When using several LDU‑X, different layer heights and materials can be used. The programmer needs to …

100%1 / 100
5 Working with the LDU‑X
5.1 Removing the transportation fastenings
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 49
5 Working with the LDU‑X
5.1 Removing the transportation fastenings
The LDU-X downholder is secured with a cable tie for transportation purposes.
► Remove this cable tie before putting the LDU-X into operation.
Fig.3: Removing the transportation fastenings
5.2 Configuring the LDU‑X
NOTICE
To prevent small components from falling into the LDU‑X application unit, make sure that
these components are not configured in the direct vicinity of the LDU-X. Where possible,
keep the area around the LDU-X free or set feeders for larger components up there (BGAs,
connectors).
CAUTION
Do not place the linear feeder directly next to the LDU-X
The vibration of a linear feeder which is directly next to the LDU-X can have a negative ef-
fect on the coating of components during the dipping process.
Do not set up any linear feeder modules directly next to the LDU-X.
Leave at least one track free to the left and right of the LDU-X or set the linear feeder up at
another location.
5.2.1 SIPLACE PRO
Component Editor
In the Component Editor you can mark components for dipping.
Component Shape Editor
The dipping mode can be programmed in the Component Shape Editor, as can various dipping
parameters, such as the order of Vision/dipping and the dipping dwell time etc..
5 Working with the LDU‑X
5.2 Configuring the LDU‑X
50 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
Setup
When using several LDU‑X, different layer heights and materials can be used. The programmer
needs to make sure that the required components are configured at the same placement location
as the LDU-X.
The LDU-X is set up on a table in the same way as a conventional feeder.
Restrictions
You can only configure one LDU-X per placement location (table).
You can set up as many LDU-Xs per machine as there are X table locations.
e.g. X machine = 4 locations = 4 LDU-X
► Select theFeeders tab.
► Open the My Tape Feeder Types folder.
► Scroll down in the My Tape Feeder Types folder.
► Select Linear Dipping Unit X.
► Drag the Linear Dipping Unit X icon with the mouse onto the changeover table.
The LDU-X will be shown on the changeover table setup in green.
5 Working with the LDU‑X
5.2 Configuring the LDU‑X
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 51
5.2.2 Handling
► Carry the LDU-X as horizontally as possible, with both hands.
5.2.3 Configuring the LDU-X
There are no restrictions for setting up the LDU‑X on a changeover table. You can configure an X
changeover table fully, with the LDU‑X and the corresponding feeders.
► (1) Configure the LDU‑X at the relevant track of the changeover table.
► (2) Push the LDU‑X up to the end stop in the track.
► (3) Press the LDU‑X firmly against the stop, so that the LDU‑X engages.
ð The LDU-X will switch on automatically and will log on to the machine.
NOTICE
Configure the LDU‑X first
To set up the LDU‑X you need a certain amount of space to the right and left of the LDU-X.
► Place the LDU‑X onto the changeover table first.
► Align the LDU‑X (planarity)
► Now place the remaining feeders onto the changeover table.