6 Maintenance
6.2 Cleaning
62 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
CAUTION
Proper disposal
The flux and cleaning agents used may contain substances which are hazardous to the en-
vironment. Read through the relevant safety data sheet and pay particular attention to the
instructions for environmental protection (ecology) and disposal.
► Dispose of used cleansing tissues in the containers provided.
6.2.3 Refit the cleaned parts
► Go to the SERVICE FUNCTIONS menu and select FITTING SYSTEM.
► Press the ENTER button.
The following section shows the messages which appear on the LDU-X display, explaining the or-
der in which the individual dip components are to be fitted again. For a detailed and illustrated de-
scription, refer to chapter 4.3.2.1.2.4 "FITTING SYSTEM function" [}36].
If you want to begin or continue production, after the dip component cleaning cycle, insert the flux
tank and fill it immediately with flux.
CAUTION
Always use flux when operating the LDU-X.
If you operate the LDU-X without flux, there is a risk that the flux tank and plates may
scrape against one another. The flux acts as lubrication for these parts.
► Always use flux when operating the LDU-X.
7 Options
7.1 Level sensor
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 63
7 Options
7.1 Level sensor
The level sensor is responsible for monitoring the amount of flux in the flux tank. During the produc-
tion process, the level of flux will fall. If the amount of flux no longer completely fills the cavity in the
dip plate, this means that the components can no longer be coated with flux to the quality required.
7.1.1 Retrofitting the level sensor
Prerequisite
A level sensor can be retrofitted in the LDU-X from function state 2 (FS2) onwards.
The FS2 can be set by the Service team.
Equipment required
●
Standard tools
●
LDU flux level sensor [00117071-xx]
7.1.1.1 Opening the LDU-X
► Remove the top cover.
► Remove the dip plate.
7 Options
7.1 Level sensor
64 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
Remove the coating jar:
► (1) Move the catch of the downholder to
the OPEN position.
► (2) Lift the downholder.
► (3) Remove the coating jar and lower the
downholder again.
► Push the slide unit forwards.
► Remove the park plate.
Remove the side cover plates:
► Place the LDU-X down on its right-hand
side, on a soft and stable surface.
► Loosen the 6 screws marked in the dia-
gram.
► Lift up the left cover plate.
► Place the LDU-X down on its left-hand
side, on a soft and stable surface.
► Loosen the 6 screws (same as for left
cover plate).
► Lift up the right cover plate.
Remove the middle cover:
► Stand the LDU-X up again.
► Loosen the 3 screws marked in the dia-
gram.