00196749-02_UM_LDU-X_EN.pdf - 第89页
8 Process Technology 8.6 Dipping procedure for TwinHead Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 89 Procedure: Vision – Dipping Component does not need to be rotated for dip- ping: 1. The placement head…

8 Process Technology
8.6 Dipping procedure for TwinHead
88 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
Procedure: Dipping - Vision
Component does not need to be rotated for dip-
ping:
1. The placement head moves over the feeder.
2. The placement head picks a component up from
the feeder.
3. The placement head moves with the component
to the LDU-X.
4. The placement head dips the component into the
flux.
5. The placement head moves the dipped compo-
nent past the component camera. While doing
this, the head rotates the component into the
rough placement angle (rotate before centering).
6. The component is measured optically and rotated
into the correct placement angle.
7. The placement head moves the component to
the board.
8. The placement head then places the component
on the board.
Component needs to be rotated for dipping:
1. The placement head moves over the feeder.
2. The placement head picks a component up from
the feeder.
3. The placement head moves with the component
to the LDU-X. The component is rotated into the
dipping angle.
4. The placement head dips the component into the
flux.
5. The placement head moves the dipped compo-
nent past the component camera. While doing
this, the head rotates the component into the
rough placement angle (rotate before centering).
6. The component is measured optically and rotated
into the correct placement angle.
7. The placement head moves the component to
the board.
8. The placement head then places the component
on the board.

8 Process Technology
8.6 Dipping procedure for TwinHead
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 89
Procedure: Vision – Dipping
Component does not need to be rotated for dip-
ping:
1. The placement head moves over the feeder.
2. The placement head picks a component up from
the feeder.
3. The placement head moves the component past
the component camera. While doing this, the
head rotates the component into the rough place-
ment angle (rotate before centering).
4. The component is measured optically and rotated
into the correct placement angle.
5. The placement head moves with the component
to the LDU-X.
6. The placement head dips the component into the
flux.
7. The placement head moves the component to
the board.
8. The placement head then places the component
on the board.
Component needs to be rotated for dipping:
1. The placement head moves over the feeder.
2. The placement head picks a component up from
the feeder.
3. The placement head moves the component past
the component camera. While doing this, the
head rotates the component into the rough place-
ment angle (rotate before centering).
4. The component is measured optically and rotated
into the dipping angle.
5. The placement head moves with the component
to the LDU-X.
6. The placement head dips the component into the
flux.
7. The placement head moves the component to
the board. While doing this, the component is ro-
tated into the placement angle.
8. The placement head then places the component
on the board.

8 Process Technology
8.7 Dipping Procedure for C&P Head
90 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
8.7 Dipping Procedure for C&P Head
In contrast to the TwinHead, the C&P head can only support the following procedure:
1. Pick up components
2. Dip components
3. Optically measure components
4. Rotate components into placement angle
5. Place components
View from above of placement machine with C&P
head
1. Placement head
2. Component camera (fitted in the placement
head)
3. Feeder module
4. LDU‑X
5. Changeover table
6. Board conveyor
7. PCB