00196749-02_UM_LDU-X_EN.pdf - 第32页
4 Software Description 4.3 Menu Description 32 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 ► Open the fixture on the hose clamp. ► Lift the cartridge out. ► Pull the hose off the tube. ► Place the tube in …

4 Software Description
4.3 Menu Description
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 31
The LDU-X display will then show the following message.
If you do not yet have enough flux in the tank:
► Select NO.
► Press the ENTER button.
► Repeat the procedure as described above.
If you do have enough flux in the tank:
► Select YES.
► Press the ENTER button.
CLEANING function
This function is used to remove the dip components to be cleaned from the LDU-X.
The squeegee moves forwards onto the dip plate.
► Wait until the squeegee has moved com-
pletely onto the dip plate.
► Remove the cover.
► Open the service lid.
The LDU-X display will show the following message:
(only in LDU-X options with refill unit)
► Disconnect the hose from the flux tank.

4 Software Description
4.3 Menu Description
32 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
► Open the fixture on the hose clamp.
► Lift the cartridge out.
► Pull the hose off the tube.
► Place the tube in the cleaning tub.
► Pull the hose attachment and hose up-
wards and out of the LDU-X.
► Place the hose attachment and hose in the
cleaning tub.

4 Software Description
4.3 Menu Description
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 33
► Clean the plunger.
► Press the ENTER button.
The LDU-X display will show the following message:
► Press the lock and push it to the right, into
the OPEN position.
► Swing the downholder up again.
► Push the flux tank forwards, onto the cen-
ter of the dip plate.
► Lower the downholder.
► Press the ENTER button.