5 Working with the LDU‑X 5.3 Monitoring production Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 57 5.3 Monitoring production During production, we recommend that the LDU‑X is checked every 2 hours for corre…

5 Working with the LDU‑X
5.2 Configuring the LDU‑X
56 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
Setting the planarity:
► First set the front screw and then the back one.
► Loosen the M4 Allen screw by about one half a rotation with a 3 mm Allen key. This takes the
tension off the cup springs slightly.
► Use a 9 mm fork wrench to turn the adjusting screw in the required direction.
► If you need to adjust with multiple revolutions, loosen or tighten the Allen screw so that the
cup springs are always tensioned.
► Check the setting by performing height measurement again. Repeat the setting until the relat-
ive values for measuring points 2 and 3 are lower than +/- 50 µm.
► Tighten the M4 Allen screw until the cup springs are pressed together completely. Use the
fork wrench to hold the adjusting screw in its position, so that this is not turned further when
you tighten the Allen screw.
View from the front, front adjusting screw
The two adjusting screws have a fine thread with a rise of 0.5 mm per revolution. If the adjusting
screw is turned one rotation, the base plate will be raised or lowered by 0.5 mm. This leverage
causes different values in the cavity of the dip plate. The diagrams show the corresponding height
changes at the corners of the cavity.
View from the side, rear adjusting screw

5 Working with the LDU‑X
5.3 Monitoring production
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 57
5.3 Monitoring production
During production, we recommend that the LDU‑X is checked every 2 hours for correct functioning.
Perform the following points:
► Use a suitable measuring device to check the required flux layer height in the cavity in the dip
plate.
► Check the level of flux in the flux tank. The inside of the flux tank has two lines (minimum /
maximum level).
► Fill in more flux if necessary.
► Check the downholders on the outside of the flux tank for contaminants.
► Clean the downholders, if necessary. You should be able to slightly tip the flux tank back and
forth in the downholders.
► Check the application unit for any leakage.
► Remove any flux which leaks out.
► Check whether there are components or other contaminants on the application unit, in the
cavity or in the flux or flux tank.
► Stop the production process and remove these contaminants with a pair of tweezers or clean
the complete LDU‑X application unit.
WARNING
Components or other contaminants on or in the application unit can cause consider-
able damage to the LDU‑X!
► Remove any contaminants immediately from the LDU‑X.
Clean the LDU-X after use.
Do not leave the LDU-X standing for longer periods with the flux inside. The flux could dry out and
clog up the LDU-X mechanics. There is then a risk that the mechanics are damaged when you re-
start the machine.
Clean the LDU-X after each shift during the production process.
Clean the LDU-X at least once a day.
Clean the LDU-X when it is taken out of the production process.
Flux counter
The flux counter enables you to roughly monitor the flux level.
The flux counter can be switched on in the Production Parameters menu and the number of coat-
ing cycles to be performed can be set to a default value, derived from current production experi-
ence.
The flux counter counts backwards after each coating application. Once zero is reached, a warning
is issued and the "cycles left" are performed. You have the chance now or after the remaining
cycles to refill the flux and set the flux counter back to the starting value.
Once the "cycles left" (remaining cycles) have been performed, the LDU-X will issue an error mes-
sage and switch over to the state "Not Ready".
After refilling, the counter is set back to the starting value.
Monitoring the waiting period
If coating is not performed for a long time, the flux can dry on the dipping area.
Normally, the station software should ensure regular coating. In addition, the LDU-X can monitor
the coating breaks (PRODUCTION PARAMETERS / MAX. PAUSE). If the break takes longer than
the set interval in minutes, the LDU-X will switch over to the state "Not Ready".

5 Working with the LDU‑X
5.3 Monitoring production
58 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
Maintenance interval
To ensure observance of the cleaning cycles, a maintenance monitor can be enabled. This shows
the time until the next cleaning run in the production menu. This can be set at PRODUCTION
PARAMETERS / CLEANING IN MIN . A cleaning warning can also be set which reminds the user
that cleaning will soon be required. Once the time has expired, the LDU switches over to the state
"Not Ready".