00196749-02_UM_LDU-X_EN.pdf - 第74页

7 Options 7.2 Refill Unit 74 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 Screw the cover plate to the board shown: ► Loosen the 3 screws marked in the dia- gram. The fourth screw (top right) remains fasten…

100%1 / 100
7 Options
7.2 Refill Unit
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 73
Remove the side cover plates:
► Place the LDU-X down on its right-hand
side, on a soft and stable surface.
► Loosen the 6 screws marked in the dia-
gram.
► Lift up the left cover plate.
► Place the LDU-X down on its left-hand
side, on a soft and stable surface.
► Loosen the 6 screws (same as for left
cover plate).
► Lift up the right cover plate.
Remove the lower cover plate:
► Place the LDU-X down on its side, on a
soft and stable surface.
► Loosen the 5 screws marked in the dia-
gram.
► Turn the LDU-X onto its other side.
► Loosen the sixth screw.
► Pull off the bottom cover plate.
7.2.1.2 Installing the refill unit
NOTICE
Removing the refill unit
To remove the refill unit again, follow the above instructions in reverse order.
► Screw an additional cover plate on at the
bottom, onto the LDU-X frame (2screws).
7 Options
7.2 Refill Unit
74 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
Screw the cover plate to the board shown:
► Loosen the 3 screws marked in the dia-
gram. The fourth screw (top right) remains
fastened.
► Fasten the cover plate with the 3 screws
marked in the diagram. Use one of the
spacers provided for each of the screws
between the board and the cover plate.
► Push the diode into the opening shown in
the diagram, as far as the stop.
► Fix the cable to the diode with a cable tie.
► Loosen the two screws on the refill unit as
marked in the diagram.
► Remove the plate from the refill unit.
7 Options
7.2 Refill Unit
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 75
► Pull the flat ribbon cable for the refill unit
into the LDU-X frame.
► Push the refill unit from behind, into the
LDU_X frame.
 CAUTION!
Make sure that you can see the holes for
the refill unit screws through the holes in
the frame.
.
► Loosely fasten the refill unit with 2 screws,
so that the refill unit can still be moved.
► Align the refill unit straight on the frame.
 CAUTION!
Make sure that the flap can still be closed.
.
► Once the refill unit is in the correct posi-
tion, tighten the two screws.
► Fix the cable into place with a cable tie, as
shown in the diagram, so that the cable is
not trapped, causing the refill unit to jam.