00196749-02_UM_LDU-X_EN.pdf - 第73页

7 Options 7.2 Refill Unit Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 73 Remove the side cover plates: ► Place the LDU-X down on its right-hand side, on a soft and stable surface. ► Loosen the 6 screws mar…

100%1 / 100
7 Options
7.2 Refill Unit
72 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
7.2.1.1 Opening the LDU-X
► Remove the top cover.
► Remove the dip plate.
Removing the coating jar:
► (1) Move the catch of the downholder to
the OPEN position.
► (2) Lift the downholder.
► (3) Remove the coating jar and lower the
downholder again.
► Push the slide unit forwards.
► Remove the park plate.
7 Options
7.2 Refill Unit
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 73
Remove the side cover plates:
► Place the LDU-X down on its right-hand
side, on a soft and stable surface.
► Loosen the 6 screws marked in the dia-
gram.
► Lift up the left cover plate.
► Place the LDU-X down on its left-hand
side, on a soft and stable surface.
► Loosen the 6 screws (same as for left
cover plate).
► Lift up the right cover plate.
Remove the lower cover plate:
► Place the LDU-X down on its side, on a
soft and stable surface.
► Loosen the 5 screws marked in the dia-
gram.
► Turn the LDU-X onto its other side.
► Loosen the sixth screw.
► Pull off the bottom cover plate.
7.2.1.2 Installing the refill unit
NOTICE
Removing the refill unit
To remove the refill unit again, follow the above instructions in reverse order.
► Screw an additional cover plate on at the
bottom, onto the LDU-X frame (2screws).
7 Options
7.2 Refill Unit
74 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
Screw the cover plate to the board shown:
► Loosen the 3 screws marked in the dia-
gram. The fourth screw (top right) remains
fastened.
► Fasten the cover plate with the 3 screws
marked in the diagram. Use one of the
spacers provided for each of the screws
between the board and the cover plate.
► Push the diode into the opening shown in
the diagram, as far as the stop.
► Fix the cable to the diode with a cable tie.
► Loosen the two screws on the refill unit as
marked in the diagram.
► Remove the plate from the refill unit.