REFILL UNIT submenu
REFILL FLUX Opens the flux refill function.
FIRST FILLING Opens the function for first filling the LDU-X with flux, using the re-
fill unit.
CHANGE CARTRIDGE The plunger moves back into the cartridge change position.
FIND CARTRIDGE The plunger moves forwards, until it has contact with the cartridge.
SINGLE REFILL The plunger presses a unit of flux into the flux tank.
Service functions
WARNING
Always wear the appropriate personal protective equipment for service work.
Observe the applicable safety data sheets for the flux and cleaning agents used.
► Use personal protective gear such as goggles, gloves, masks, suction units etc. when
performing service work.
SINGLE CYCLE function
With the help of the single cycle, a task can be performed manually at the LDU‑X. In this case, the
flux tank moves forwards, applies flux to the dip plate and then moves back into the basic position.
FLUX REFILL function
This function is automatically opened if the level sensor determines that the level of flux is too low.
You can also open this function manually.
FLUX REFILL with refill unit
The LDU-X display will show the following message:
The plunger moves back into the cartridge change position.
► Wait until the plunger has been moved fully
back.
► Remove the cover.
► Open the service lid.
4 Software Description
4.3 Menu Description
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 27
► Open the fixture on the hose clamp.
► Lift the cartridge out.
► Pull the hose off the tube.
► Place the tube in the cleaning tub.
► (1) Twist the top off the new cartridge.
► (2) Insert one end of the hose as far as
possible onto the cartridge.
4 Software Description
4.3 Menu Description
28 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
► (1) Hold the hose at the front, on the cart-
ridge.
► (2) Insert the rubber plug as far as possible
into the cartridge. Make sure that no air
pockets are formed in the cartridge.
► Insert the cartridge first at the top(1) and
then at the bottom(2).
► (1) Close the hose clamp.
► (2) Make sure that the fixture engages
properly.
► Press the hose behind the side panel.
► Press the ENTER button.