4 Software Description 4.3 Menu Description 34 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 The LDU-X display will show the following message: (only in function states 1 and 2). NOTICE In function states 1 …

100%1 / 100
4 Software Description
4.3 Menu Description
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 33
► Clean the plunger.
► Press the ENTER button.
The LDU-X display will show the following message:
► Press the lock and push it to the right, into
the OPEN position.
► Swing the downholder up again.
► Push the flux tank forwards, onto the cen-
ter of the dip plate.
► Lower the downholder.
► Press the ENTER button.
4 Software Description
4.3 Menu Description
34 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
The LDU-X display will show the following message:
(only in function states 1 and 2).
NOTICE
In function states 1 and 2, the downholder must be fixed in the raised position, so that it
does not catch on the dip plate when moving forwards.
In function state 3, the downholder does not need to be fixed.
► Swing the downholder up again.
► (1) Press the lock and push it to the left,
into the CLOSED position.
► Lower the downholder.
► Press the ENTER button.
The squeegee moves back onto the park plate and the dip plate moves upwards.
The LDU-X display will show the following message:
► Remove the dip plate, together with the
flux tank.
► Press the ENTER button.
The squeegee moves right to the front, so that the park plate and the dip tray can be easily re-
moved.
4 Software Description
4.3 Menu Description
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 35
The LDU-X display will show the following message:
► Lift the level sensor.
► Remove the park plate (1).
► Place the park plate in the cleaning tub.
Make sure that you do not dirty the level
sensor during removal.
► Remove the dip tray (2).
► Place the dip tray in the cleaning tub.
► Lower the level sensor.
► Press the ENTER button.
The LDU-X display will show the following message:
► Close the cover.
► Close the service lid.
► Clean the removed dip components as described in chapter 6.2 "Cleaning" [}59].
► Press the ENTER button.
► Continue with the FITTING SYSTEM function.