7 Options
7.1 Level sensor
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 63
7 Options
7.1 Level sensor
The level sensor is responsible for monitoring the amount of flux in the flux tank. During the produc-
tion process, the level of flux will fall. If the amount of flux no longer completely fills the cavity in the
dip plate, this means that the components can no longer be coated with flux to the quality required.
7.1.1 Retrofitting the level sensor
Prerequisite
A level sensor can be retrofitted in the LDU-X from function state 2 (FS2) onwards.
The FS2 can be set by the Service team.
Equipment required
●
Standard tools
●
LDU flux level sensor [00117071-xx]
7.1.1.1 Opening the LDU-X
► Remove the top cover.
► Remove the dip plate.
7 Options
7.1 Level sensor
64 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
Remove the coating jar:
► (1) Move the catch of the downholder to
the OPEN position.
► (2) Lift the downholder.
► (3) Remove the coating jar and lower the
downholder again.
► Push the slide unit forwards.
► Remove the park plate.
Remove the side cover plates:
► Place the LDU-X down on its right-hand
side, on a soft and stable surface.
► Loosen the 6 screws marked in the dia-
gram.
► Lift up the left cover plate.
► Place the LDU-X down on its left-hand
side, on a soft and stable surface.
► Loosen the 6 screws (same as for left
cover plate).
► Lift up the right cover plate.
Remove the middle cover:
► Stand the LDU-X up again.
► Loosen the 3 screws marked in the dia-
gram.
7 Options
7.1 Level sensor
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 65
7.1.1.2 Installing the level sensor
NOTICE
The level sensor is preset at the factory. Do not change these settings.
► Fasten the angle fixture bracket with two
screws to the position shown in the dia-
gram.
► Fasten the level sensor with two screws to
the position shown in the diagram.
 CAUTION!
Make sure that the level sensor is aligned
straight on the slide.
.
Connecting the fiber optic cable to the control
unit:
► Connect the marked cable to the top con-
nection.
► Connect the other cable to the bottom con-
nection.
► Lock the control unit into place.
► Run the cable as shown in the diagram.
► Screw the control unit to the angle fixture
bracket with two screws.