7 Options 7.2 Refill Unit Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 75 ► Pull the flat ribbon cable for the refill unit into the LDU-X frame. ► Push the refill unit from behind, into the LDU_X frame.  C…

100%1 / 100
7 Options
7.2 Refill Unit
74 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
Screw the cover plate to the board shown:
► Loosen the 3 screws marked in the dia-
gram. The fourth screw (top right) remains
fastened.
► Fasten the cover plate with the 3 screws
marked in the diagram. Use one of the
spacers provided for each of the screws
between the board and the cover plate.
► Push the diode into the opening shown in
the diagram, as far as the stop.
► Fix the cable to the diode with a cable tie.
► Loosen the two screws on the refill unit as
marked in the diagram.
► Remove the plate from the refill unit.
7 Options
7.2 Refill Unit
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 75
► Pull the flat ribbon cable for the refill unit
into the LDU-X frame.
► Push the refill unit from behind, into the
LDU_X frame.
 CAUTION!
Make sure that you can see the holes for
the refill unit screws through the holes in
the frame.
.
► Loosely fasten the refill unit with 2 screws,
so that the refill unit can still be moved.
► Align the refill unit straight on the frame.
 CAUTION!
Make sure that the flap can still be closed.
.
► Once the refill unit is in the correct posi-
tion, tighten the two screws.
► Fix the cable into place with a cable tie, as
shown in the diagram, so that the cable is
not trapped, causing the refill unit to jam.
7 Options
7.2 Refill Unit
76 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
► Push the lower cover plate onto the LDU-
X.
Screwing the lower cover plate into place:
► Fasten the 5 screws marked in the dia-
gram.
► Turn the LDU-X onto its other side.
► Fasten the sixth screw.
► Run the cable behind the plate.
► Screw the plate to the refill unit.
► Stand the LDU-X upright again.
► Loosen the LDU-X base unit.