4 Software Description 4.4 Error Messages Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 45 4.3.2.4 SYSTEM INFORMATION menu LANGUAGE Language selection German/English HARDWARE VERSION Hardware function state …

4 Software Description
4.3 Menu Description
44 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
4.3.2.3 SYSTEM PARAMETERS menu
SYSTEM POSITIONS Sets the hold positions for the motors and motor parameters
CHANGE PASSWORD Enables you to change the password
LOAD DEFAULT Loads the preset parameter values
RESET SYSTEM Resets the LDU-X to its original (delivery) state
System positions submenu
TEACH X-POSITIONS Save the current X position as baseline value
TEACH Y-POSITIONS Save the current Y position as baseline value
PARAMETER X-AXIS Set the X positions and motor parameters
PARAMETER Z-AXIS Set the Z positions and motor parameters
The following parameters from the above mentioned functions can be set:
ZERO POS X/Z zero position (park plate and dip plate at same height)
X-REVERS POS Front reverse position of squeegee
X-ADJ POS Control position for sensor
X-SPDUP POS If the coating speed is reduced, the speed will be accelerated
again from this point
VELOCITY Speed outside the coating area.
ACCELER X/Z acceleration
POS ERR X/Z permissible position error
CHANGE POS Position for tank change
Z-DIPPOS Height of dip plate for dipping
Z-MOT DEL Waiting time after motor movement in ms

4 Software Description
4.4 Error Messages
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 45
4.3.2.4 SYSTEM INFORMATION menu
LANGUAGE Language selection German/English
HARDWARE VERSION Hardware function state (LDU-X)
VERSION Software version
4.4 Error Messages
In the event of an error, the amber LED shines on the right of the LDU-X display and the refill unit
LED will flash. The respective error message is shown on the display. The following list shows all
error messages, sorted according to their error numbers.
4.4.1 Overview of Error Messages
Error Displays Error message topic
101 LDU WAS NOT ACTIVE!
PLEASE CHECK MEDIUM!
See Messages About Monitoring Coating Intervals
102 REFILL UNIT
NOT ACTIVE
See Messages About the Refill Unit
103 CLEANING IN MIN5 See Messages About the Cleaning Cycle
104 FLUXLEVEL LOW!
CYCLES LEFT20
See Messages About the Level Sensor
105 CARTRIDGE EMPTY
TAPPET IS MOVING
See Messages About the Refill Unit
106 CARTRIDGE EMPTY See Messages About the Refill Unit
107 REFILL NOT OK See Messages About the Refill Unit
108 SET SERVICE KEY
TO SERVICE POSITION
See Messages About the Key Switch
109 SET SERVICE KEY
TO PRODUCTION MODE
See Messages About the Key Switch
201 FLUXLEVEL LOW! See Messages About the Level Sensor
202 LEVEL SENSOR
NOT READY
See Messages About the Level Sensor
203 REFILL
UNIT BLOCKED
See Messages About the Refill Unit
204 EMERGENCY SWITCH
IS LOCKED
See Messages About the Emergency Stop
205 MISSING DIP PLATE See Messages About the Dip Plate and Dip Tray
206 PLEASE CHECK PLATES
AND
DIP TRAY
See Messages About the Dip Plate and Dip Tray
301 PLEASE CLEAN LDU See Messages About the Cleaning Cycle
302 TANK IS MOVING See Messages About the Dip Plate and Dip Tray

4 Software Description
4.4 Error Messages
46 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
4.4.2 Messages About the Level Sensor
Error Displays Description
104 FLUXLEVEL LOW!
CYCLES LEFT20
The level sensor has determined that there is not
enough flux present. CYCLES LEFT shows how often
coating will still be performed before the LDU-X
switches over to "Not Ready".
201 FLUXLEVEL LOW! The remaining cycles have been performed.
The LDU-X is now in the state "Not Ready".
202 LEVEL SENSOR
NOT READY
The control measurement by the sensor was unsuc-
cessful.
The LDU-X is in the state "Not Ready".
4.4.3 Messages About the Refill Unit
Error Displays Description
102 REFILL UNIT
NOT ACTIVE
The refill unit has been switched off or is not present.
105 CARTRIDGE EMPTY
TAPPET IS MOVING
The cartridge is empty and the plunger is being moved
back.
Wait until the plunger has been moved back.
106 CARTRIDGE EMPTY The cartridge is empty and the plunger is in the starting
position.
107 REFILL NOT OK After 3x filling, there is still not enough flux in the tank.
Check the flux supply for air in the hose or cartridge, a
torn or folded hose.
203 REFILL
UNIT BLOCKED
The refill unit is blocked and the plunger can not be
moved. Check the flux supply for folded hose or ex-
cessive fluid viscosity.
4.4.4 Messages About Monitoring Coating Intervals
Error Displays Description
101 LDU WAS NOT ACTIVE!
PLEASE CHECK MEDIUM!
The time interval since the last coating is too long.
The LDU-X was switched off or was already in service
mode.
Check the flux. If necessary, clean the dip elements
and refill the flux.
4.4.5 Messages About the Cleaning Cycle
Error Displays Description
103 CLEANING IN MIN5 The LDU-X will remain in the "ready" state for the num-
ber of minutes shown.
301 PLEASE CLEAN LDU The LDU-X is now in the state "Not Ready".
4.4.6 Messages About the Dip Plate and Dip Tray
Error Displays Description
205 MISSING DIP PLATE Insert the dip plate.
206 PLEASE CHECK PLATES
AND
DIP TRAY
Press the ENTER button.
Insert the dip plate, park plate and dip tray.
302 TANK IS MOVING Wait until the coating movement has been completed.