4 Software Description
4.3 Menu Description
42 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
The LDU-X display will show the following message:
The LDU-X will now begin filling. The flux is pressed into the hose and coated alternately, until the
set flux level has been reached.
Once the set level of flux has been reached, the LDU-X automatically performs the function WARM UP.
WARM UP function
With the help of this warm up function, the flux in the LDU‑X can be prepared so that it is ready for
operation. This performs a set number of single cycles in succession until the defined warm up time
has expired. This movement "warms up" the flux.
INITIALIZATION function
With the initialization function, the LDU‑X can be brought into a defined basic position. If initializa-
tion is performed successfully, you can assume that the electrical and mechanical functions of the
LDU-X are OK.
Initialization procedure
The axes can have any initial starting position. Firstly, the Z axis (dip plate) is moved down to the Z
sensor. After this, the X axis (flux tank) is moved to the X init sensor in the basic position.
4 Software Description
4.3 Menu Description
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 43
4.3.2.2 PRODUCT PARAMETERS menu
The production parameters can be set in this menu.
NOTICE
The values shown in this section are the defaults for the individual parameters.
REFILL UNIToff Switches the refill unit on and off
LEVEL SENSORoff Switches the level sensor on and off
REFILL COUNTEROn Switches the refill counter on and off
REFILL COUNTER5000 Starting value for the refill counter
MAX.PAUSEoff Switches the non-coating time check on/off
MAX.PAUSEMIN3 The maximum time in minutes during which coating may not be
performed
MAINTEN-
ANCEoff
Switches the cleaning interval check on and off
CLEANING IN MIN480 Cleaning interval duration in minutes
CLEAN WARNING5 Warning display before end of cleaning interval in minutes
SPEED250 Coating speed
CYCLES LEFT20 Number of cycles which will still be coated if a warning is issued.
This applies, for example, if the level sensor reports that the level
of flux is too low.
REFILL CYCLES3 Number of coating cycles after each flux refill
WARM UP30 Number of coating cycles during warm up
TANK VOLUME
middle
Required tank level to be monitored by the sensor
STARTWARNINGon Switches the command to check flux at start of LDU on and off
These settings are checked by the system and corrected where necessary. For example, the refill
unit does not function without the level sensor. If multiple options are enabled, these will be priorit-
ized in the order listed in the menu.
4 Software Description
4.3 Menu Description
44 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
4.3.2.3 SYSTEM PARAMETERS menu
SYSTEM POSITIONS Sets the hold positions for the motors and motor parameters
CHANGE PASSWORD Enables you to change the password
LOAD DEFAULT Loads the preset parameter values
RESET SYSTEM Resets the LDU-X to its original (delivery) state
System positions submenu
TEACH X-POSITIONS Save the current X position as baseline value
TEACH Y-POSITIONS Save the current Y position as baseline value
PARAMETER X-AXIS Set the X positions and motor parameters
PARAMETER Z-AXIS Set the Z positions and motor parameters
The following parameters from the above mentioned functions can be set:
ZERO POS X/Z zero position (park plate and dip plate at same height)
X-REVERS POS Front reverse position of squeegee
X-ADJ POS Control position for sensor
X-SPDUP POS If the coating speed is reduced, the speed will be accelerated
again from this point
VELOCITY Speed outside the coating area.
ACCELER X/Z acceleration
POS ERR X/Z permissible position error
CHANGE POS Position for tank change
Z-DIPPOS Height of dip plate for dipping
Z-MOT DEL Waiting time after motor movement in ms