00196749-02_UM_LDU-X_EN.pdf - 第87页
8 Process Technology 8.6 Dipping procedure for TwinHead Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 87 8.6 Dipping procedure for TwinHead There are two dipping modes possible in the placement machines for …

8 Process Technology
8.5 Parameters for the application process
86 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
8.5 Parameters for the application process
Application procedure
1. The flux tank moves at maximum X-axis speed into the reverse position (5).
2. The flux tank is now in reverse position (8).
3. The flux tank moves with set X-axis application speed (6) over the cavity and into the acceler-
ation position(9).
4. The flux tank moves at maximum X-axis speed (7) into the park position(10).
Application speed
The speed with which the flux tank moves over the cavity can be set in the menu PRODUCT
PARAMETER / SPEED.
This parameter has a great influence on the surface of the flux after application
The optimum speed for the medium used needs to be determined in tests. It is therefore useful to
use the following standard speeds as a starting point:
●
Flux = 250
●
Solder paste = 100

8 Process Technology
8.6 Dipping procedure for TwinHead
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 87
8.6 Dipping procedure for TwinHead
There are two dipping modes possible in the placement machines for TwinHead:
●
Dipping – Vision:
The component is first moved via the LDU-X, is dipped and then optically measured by the
component camera.
●
Vision – Dipping:
The component is first moved past the component camera, is optically measured and is then
sent via the LDU-X for dipping.
It should be taken into account that there are cases in which the component will not fit into the
LDU-X cavity when it is in its pickup angle position. If it does not fit in across the width, it will need
to be rotated before dipping.
In the following example, a wide connector strip is picked up from a tray. In its original angle posi-
tion, this does not fit widthwise into the cavity (1) and needs to be rotated by 90° before dipping (2).
The decision as to whether a component needs to be rotated or not is automatically made by the
station software, based on the component shape dimensions. The rotation process can not be
manually influenced on the software interface.
View from above of placement machine with TwinHead
1. Placement head (TwinHead)
2. Changeover table
3. Feeder module
4. LDU-X
5. Component camera (fitted in the machine
frame)
6. Board conveyor
7. PCB

8 Process Technology
8.6 Dipping procedure for TwinHead
88 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
Procedure: Dipping - Vision
Component does not need to be rotated for dip-
ping:
1. The placement head moves over the feeder.
2. The placement head picks a component up from
the feeder.
3. The placement head moves with the component
to the LDU-X.
4. The placement head dips the component into the
flux.
5. The placement head moves the dipped compo-
nent past the component camera. While doing
this, the head rotates the component into the
rough placement angle (rotate before centering).
6. The component is measured optically and rotated
into the correct placement angle.
7. The placement head moves the component to
the board.
8. The placement head then places the component
on the board.
Component needs to be rotated for dipping:
1. The placement head moves over the feeder.
2. The placement head picks a component up from
the feeder.
3. The placement head moves with the component
to the LDU-X. The component is rotated into the
dipping angle.
4. The placement head dips the component into the
flux.
5. The placement head moves the dipped compo-
nent past the component camera. While doing
this, the head rotates the component into the
rough placement angle (rotate before centering).
6. The component is measured optically and rotated
into the correct placement angle.
7. The placement head moves the component to
the board.
8. The placement head then places the component
on the board.