00196749-02_UM_LDU-X_EN.pdf - 第17页
3 Hardware Description 3.1 Controls Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 17 3 Hardware Description 3.1 Controls 1. Control panel on the upper side 2. Flap for refill unit 3. Handle 4. Warning instru…

2 Overview
2.4 Requirements and restrictions
16 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017

3 Hardware Description
3.1 Controls
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 17
3 Hardware Description
3.1 Controls
1. Control panel on the upper side
2. Flap for refill unit
3. Handle
4. Warning instructions
5. EMERGENCY STOP button
6. Service switch
3.2 Operator panel
1. Display (4 lines, each with 20 char-
acters)
2. LED for refill unit *
3. ENTER button
4. ESC button
5. SELECT UP button
6. SELECT DOWN button
7. VALUE button + (plus)
8. VALUE button – (minus)
9. Green status lamp
10. Yellow status lamp
11. Amber status lamp
12. Red status lamp
*Only present if the LDU-X is fitted with a
refill unit.

3 Hardware Description
3.3 Status Indicator
18 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
3.3 Status Indicator
LED LDU‑X state
All LEDs LDU‑X is installed
Green LDU-X is ready
Green + red Coating command
Yellow Service mode
Amber Warning that the LDU-X will soon switch over to "Not Ready"
(e.g. not enough flux, maintenance required)
Coating is still being performed and dipping is still possible.
Red LDU‑X is not ready for operation (e.g. error, no flux)
Dipping is no longer possible.
LED for refill unit
Off No message
Flashes Warning that the LDU-X will soon switch over to "Not Ready"
(as above at "amber")
Continuous light LDU‑X is not ready for operation
(as above, under "red")
3.4 LDU‑X design
1. Dip plate with cavity
2. Flux tank
3. Level sensor (option)
4. Cover (only for function states 1 and 2)
5. Lock for flux tank
6. Downholder