4 Software Description 4.3 Menu Description Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 29 The LDU-X display will show the following message: ► (1) Check again whether the rubber plug has been inserted cor…

4 Software Description
4.3 Menu Description
28 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
► (1) Hold the hose at the front, on the cart-
ridge.
► (2) Insert the rubber plug as far as possible
into the cartridge. Make sure that no air
pockets are formed in the cartridge.
► Insert the cartridge first at the top(1) and
then at the bottom(2).
► (1) Close the hose clamp.
► (2) Make sure that the fixture engages
properly.
► Press the hose behind the side panel.
► Press the ENTER button.

4 Software Description
4.3 Menu Description
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 29
The LDU-X display will show the following message:
► (1) Check again whether the rubber plug
has been inserted correctly into the cart-
ridge.
► (2) Check again whether the hose clamp
fixture has engaged properly.
► Close the cover.
► Close the service lid.
► Press the ENTER button.
The LDU-X display will show the following message:
The LDU-X will now begin filling. The flux is pressed into the hose and coated alternately, until the
set flux level has been reached.
Once the set level of flux has been reached, the LDU-X automatically performs the function WARM
UP.

4 Software Description
4.3 Menu Description
30 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
REFILLING FLUX Without Refill Unit
► Fill the flux into the flux tank. Make sure
that the maximum level is not exceeded.
► Press the ENTER button.
The LDU-X will begin coating cycles and then measures the level of the flux with the level sensor.
If the level of flux is too low, a corresponding message will be shown on the LDU-X display.
► Fill more flux into the flux tank. Make sure that the maximum level is not exceeded.
► Press the ENTER button.
Repeat this procedure until there is enough flux in the tray.
REFILLING FLUX Without the Level Sensor
► Fill the flux into the flux tank. Make sure
that the maximum level is not exceeded.
► Press the ENTER button.
The LDU-X will begin coating cycles.