7 Options
7.1 Level sensor
66 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
► Loose the LDU-X base unit from the X ad-
apter (2 screws).
► Lift the LDU-X base unit to one side.
NOTICE!
Connect the control unit cable to the
terminal strip:
Observe the safety instructions in the ESD
guidelines.
.
► Press the terminal in.
► Plug in the cable.
► Let the terminal go.
► Lift the LDU-X base unit back onto the X
adapter.

7 Options
7.1 Level sensor
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 67
► Screw the LDU-X base unit to the X ad-
apter.
Fastening the side cover plates:
► Place the LDU-X down on its right-hand
side, on a soft and stable surface.
► Place the left cover plate the right way
onto the LDU-X.
► Fix with the 6 screws.
► Place the LDU-X down on its left-hand
side, on a soft and stable surface.
► Place the right cover plate the right way
onto the LDU-X.
► Fix with the 6 screws.
7.1.1.3 Checking the Light Conductor
► Connect the LDU-X to a power source.
This can be:
●
a Single Slot EDIF
●
the changeover table of the machine
► Check the light point below the level
sensor
●
Correct (left):
the light point shows a completely filled
shape.
●
Wrong (right):
the light point shows a light crown only.
If only a light crown can be seen, the light conductors are interchanged and have to be connected
properly to the control unit.
If no light point can be seen, the cables are not properly connected to the control unit. This has to
be corrected.

7 Options
7.1 Level sensor
68 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
7.1.1.4 Adjusting the control unit
The control unit has been factory adjusted but will need to be checked and possibly corrected, due
to the different reflection properties of the park plates.
► Note the measurement value shown for the control unit when the bar is swung down =
value_ON
► Note the measurement value when the bar is swung up = value_OFF
► Calculate the switching threshold = (value_ON - value_OFF) *0.2 + value_OFF
► Check the switching threshold by slowing swinging up the sensor bar.
The yellow LED for the control unit is initially switched to "on". Once the switching threshold is
reached, the LED will switch to "off". The measurement value shown at this point must correspond
to the calculated switching threshold.
If the values differentiate by more than +/-20 digits from one another, you will need to reset the
switching threshold, as described in the instructions provided. The following settings are otherwise
required:
nonc = nc
FSEt = Stnd
dlay = off
7.1.1.5 Closing the LDU-X
► Push the slide unit forwards.
► Refit the park plate.
► Push the slide unit back.
Inserting the coating jar:
► (1) Lift the downholder.
► (2) Insert the coating jar and lower the
downholder again.
► (3) Push the lock on the downholder to the
position CLOSED.