00196749-02_UM_LDU-X_EN.pdf - 第84页

8 Process Technology 8.4 Layer thickness 84 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 In the following diagram, the same component is dipped into various different dip plates. The dip plate cavity in (1)…

100%1 / 100
8 Process Technology
8.3 Travel profile
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 83
The detailed dipping procedure (step 2) consists of the following steps:
1. The placement head moves with the component over the LDU‑X to an unused part of the dip-
ping area. The Z-axis moves down, until the component reaches the bottom of the cavity. The
Z-down sensor for the placement head will signal.
2. The Z-down sensor activation starts a dwell time.
3. After the end of the dwell time, the Z-axis moves up again.
During the dwell time, the flux can coat the component on the parts which have been dipped into it.
This dwell time can be set on the line computer in SIPLACE PRO (8.8 "Dipping Parameters in
SIPLACE Pro" [}93]). The right time must be determined through tests.
8.3 Travel profile
After the end of the dwell time, the Z-axis moves up. Select a slow travel profile, meaning a gentle
approach, for this. This enables the component to be taken slowly out of the flux and gently de-
tached from the flux.
The travel profile for each component can be set on the line computer in SIPLACE PRO.
8.4 Layer thickness
The amount of flux or the layer thickness on the component depends on the thickness of the flux
layer in the cavity. The layer thickness on the cavity depends both on the cavity depth and the coat-
ing effect of the fluid used.
Influence of cavity depth on the layer thickness
The cavity depth is engraved on the top of the dip plate. The example in the diagram shows 45 µm.
8 Process Technology
8.4 Layer thickness
84 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
In the following diagram, the same component is dipped into various different dip plates. The dip
plate cavity in (1) is deeper than in (2). This means that more flux stays on the component because
the layer of flux is thicker here.
Influence of coating fluid on the layer thickness
The capillary effect describes the behavior of fluid as shown during the contact between solids and
capillaries e.g. narrow tubes, gaps or hollow spaces.
Example: if one dips a glass tube vertically into water, the water will rise up a little in the narrow
glass tube against the force of gravity. This effect is caused by the surface tension of the fluid itself
and the interfacial tension of the fluids with the solid surface.
1. Dip plate
2. Flux
3. Hollow
4. Cavity depth in the dip plate
5. Remaining flux height
Multiple measurements lead to a value for reduction of the layer thickness. This value shows that
the flux layer thickness is roughly 2/3 of the cavity depth i.e. the layer thickness is reduced by about
1/3. The following table lists the dip plates for the LDU‑X with the cavity depth and the resulting
layer thickness.
Item number Cavity depth [µm] Layer thickness [µm]
03059408-xx Blank part -
03063053-xx 20 ~ 13
03063054-xx 30 ~ 20
03063055-xx 40 ~ 26
03063056-xx 50 ~ 33
03063057-xx 60 ~ 40
03063058-xx 70 ~ 46
03063059-xx 80 ~ 53
03063060-xx 90 ~ 60
03063061-xx 100 ~66
03063106-xx 360 ~ 240
8 Process Technology
8.4 Layer thickness
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 85
Since the value of 2/3 is a rough estimate, the exact amount of flux which stays on the component
must be determined in tests. In very critical processes, dip plates with a customized cavity depth
can be supplied.
Influence of coating fluid on the dipping area
A hollow is formed in the flux at the edge of the cavity. This has a width of about one to two milli-
meters.
1. Dip plate
2. Flux
3. Width of hollow
This means that the dip plate area which can be used is smaller than the cavity itself.
1. Dip plate
2. Cavity
3. Hollow
4. Dipping area, determined by the hollow
5. Edge area, determined by the hollow
This effect is taken into account in the station software. The placement machine automatically
keeps an edge of 3 mm when dipping components. The dipping area is therefore 6 mm smaller
than the cavity itself. The cavity has a size of 75 mm x 55 mm, the available dipping area only a
size of 69 mm x 49 mm.
1. Dip plate
2. Cavity
3. Print of dipped component in the flux
4. Dipping area, determined by the software
5. 3 mm edge area, determined by the soft-
ware