00196749-02_UM_LDU-X_EN.pdf - 第86页
8 Process Technology 8.5 Parameters for the application process 86 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 8.5 Parameters for the application process Application procedure 1. The flux tank moves at max…

8 Process Technology
8.4 Layer thickness
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 85
Since the value of 2/3 is a rough estimate, the exact amount of flux which stays on the component
must be determined in tests. In very critical processes, dip plates with a customized cavity depth
can be supplied.
Influence of coating fluid on the dipping area
A hollow is formed in the flux at the edge of the cavity. This has a width of about one to two milli-
meters.
1. Dip plate
2. Flux
3. Width of hollow
This means that the dip plate area which can be used is smaller than the cavity itself.
1. Dip plate
2. Cavity
3. Hollow
4. Dipping area, determined by the hollow
5. Edge area, determined by the hollow
This effect is taken into account in the station software. The placement machine automatically
keeps an edge of 3 mm when dipping components. The dipping area is therefore 6 mm smaller
than the cavity itself. The cavity has a size of 75 mm x 55 mm, the available dipping area only a
size of 69 mm x 49 mm.
1. Dip plate
2. Cavity
3. Print of dipped component in the flux
4. Dipping area, determined by the software
5. 3 mm edge area, determined by the soft-
ware

8 Process Technology
8.5 Parameters for the application process
86 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
8.5 Parameters for the application process
Application procedure
1. The flux tank moves at maximum X-axis speed into the reverse position (5).
2. The flux tank is now in reverse position (8).
3. The flux tank moves with set X-axis application speed (6) over the cavity and into the acceler-
ation position(9).
4. The flux tank moves at maximum X-axis speed (7) into the park position(10).
Application speed
The speed with which the flux tank moves over the cavity can be set in the menu PRODUCT
PARAMETER / SPEED.
This parameter has a great influence on the surface of the flux after application
The optimum speed for the medium used needs to be determined in tests. It is therefore useful to
use the following standard speeds as a starting point:
●
Flux = 250
●
Solder paste = 100

8 Process Technology
8.6 Dipping procedure for TwinHead
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 87
8.6 Dipping procedure for TwinHead
There are two dipping modes possible in the placement machines for TwinHead:
●
Dipping – Vision:
The component is first moved via the LDU-X, is dipped and then optically measured by the
component camera.
●
Vision – Dipping:
The component is first moved past the component camera, is optically measured and is then
sent via the LDU-X for dipping.
It should be taken into account that there are cases in which the component will not fit into the
LDU-X cavity when it is in its pickup angle position. If it does not fit in across the width, it will need
to be rotated before dipping.
In the following example, a wide connector strip is picked up from a tray. In its original angle posi-
tion, this does not fit widthwise into the cavity (1) and needs to be rotated by 90° before dipping (2).
The decision as to whether a component needs to be rotated or not is automatically made by the
station software, based on the component shape dimensions. The rotation process can not be
manually influenced on the software interface.
View from above of placement machine with TwinHead
1. Placement head (TwinHead)
2. Changeover table
3. Feeder module
4. LDU-X
5. Component camera (fitted in the machine
frame)
6. Board conveyor
7. PCB