00196749-02_UM_LDU-X_EN.pdf - 第90页

8 Process Technology 8.7 Dipping Procedure for C&P Head 90 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 8.7 Dipping Procedure for C&P Head In contrast to the TwinHead, the C&P head can only supp…

100%1 / 100
8 Process Technology
8.6 Dipping procedure for TwinHead
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 89
Procedure: Vision – Dipping
Component does not need to be rotated for dip-
ping:
1. The placement head moves over the feeder.
2. The placement head picks a component up from
the feeder.
3. The placement head moves the component past
the component camera. While doing this, the
head rotates the component into the rough place-
ment angle (rotate before centering).
4. The component is measured optically and rotated
into the correct placement angle.
5. The placement head moves with the component
to the LDU-X.
6. The placement head dips the component into the
flux.
7. The placement head moves the component to
the board.
8. The placement head then places the component
on the board.
Component needs to be rotated for dipping:
1. The placement head moves over the feeder.
2. The placement head picks a component up from
the feeder.
3. The placement head moves the component past
the component camera. While doing this, the
head rotates the component into the rough place-
ment angle (rotate before centering).
4. The component is measured optically and rotated
into the dipping angle.
5. The placement head moves with the component
to the LDU-X.
6. The placement head dips the component into the
flux.
7. The placement head moves the component to
the board. While doing this, the component is ro-
tated into the placement angle.
8. The placement head then places the component
on the board.
8 Process Technology
8.7 Dipping Procedure for C&P Head
90 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
8.7 Dipping Procedure for C&P Head
In contrast to the TwinHead, the C&P head can only support the following procedure:
1. Pick up components
2. Dip components
3. Optically measure components
4. Rotate components into placement angle
5. Place components
View from above of placement machine with C&P
head
1. Placement head
2. Component camera (fitted in the placement
head)
3. Feeder module
4. LDU‑X
5. Changeover table
6. Board conveyor
7. PCB
8 Process Technology
8.7 Dipping Procedure for C&P Head
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 91
Procedure (example)
1. The placement head moves over the feeder.
2. The placement head picks the component(s) up
from the feeder e.g. 12 components in succes-
sion.
3. The placement head moves with the components
to the LDU-X.
4. The placement head dips the 12 components in
succession, into the flux.
5. The placement head moves the dipped compon-
ents to the board.
6. The placement head then places the 12 compon-
ents on the board.
Detailed procedure for C&P head
(1) All head segments are empty. Segment 1 picks up a component from a tray or feeder. Segment
5 is rotated into the pickup angle by the turning station.
The head then moves the segments on and picks up the next components in succession.
(2) Segment 9 has just picked up a component. Segments 1, 2 and 3 were under the component
camera. However, the camera is not active and the components were not measured. Segment 1 is
in the turning station. However, the turning station is not active and all components are still in the
pickup angle.
(3) The head has picked up 12 components.The gantry now moves from the feeder to the LDU-X.